Datalogic S51-PR Series Manuale di istruzioni

Sfoglia online o scarica il pdf Manuale di istruzioni per Accessories Datalogic S51-PR Series. Datalogic S51-PR Series 5.

Datalogic S51-PR Series Manuale di istruzioni
This product is covered by one or m ore of the following patents.
European Patent 1,111,690 B1
S51-PA/PR SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S51-...A00/B01/C01/C10/F00)
T he yellow LED ON indicates that the NO output status is closed.
POWER ON LED (S51-...G00)
T he green LED indicates that the sensor is operating.
TRIMMER (S51-...B01/C01)
T he trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270°.
Do not apply excessive torque beyond the maximum and minimum
positions (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through a
 18mm hole, using the specific washer and the two CH.24 nuts (1.5Nm
maximum tightening torque) or CH.22 nuts, h=8mm, (2Nm maximum
tightening torque) enclosed. Alternatively, the sensor can be mounted
through the two housing's holes using two screws (M3x22 or longer)
and washer.
Amongst the various possible solutions, we suggest to choose the
combination that offers the best visibility of the signalling LEDs and the
easiest access to the trimmer.
Various orientable fixing brackets are available
to ease the sensor positioning (please refer to
the
accessories
listed
in
the general
catalogue).
The
operating
distance
is
measured from the front surface of the sensor
lens.
C m odels: To improve the detection, the object
has to be moved closer or further away from the front surface of the
sensor lens.
In case of lateral translation, the object must move as indicated in the
figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S51-...A00/B01/C01/C10/F00
S51-...G00
BROWN
1
BROWN
1
+
+
10 ... 30 Vdc
2
WHITE
WHITE
2
*
DARK- / LIGHT+
4
4
BLACK
BLACK
N.O. OUTPUT
3
3
BLUE
BLUE
0 V
*
in case of white wire or pin 2 not connected the sensor works in LIGHT
mode for proximity models (C01/C10/C20) and in DARK mode for
retroreflex (A00/B01) and receiver (F00).
M12 CONNECTOR
2
1
3
4
AXIAL VERSION
L
2
1.5
3.5
25
X
2.5
TRIMMER
N°.2 Ø3.8
X1
15
OUTPUT LED
CH.24 PLASTIC NUTS
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating temperature:
Storage temperature:
Insulating strength:
Insulating resistance:
Operating distance
(typical values):
10 ... 30 Vdc
Emission type:
TEST +
Ambient light rejection:
TEST -
Vibrations:
Shock resistance:
0 V
white wire or pin 2 connected to +10...30V LIGHT mode; to 0V DARK mode
LIGHT/DARK selection:
white wire or pin 2 not connected
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU
DIMENSIONS
M O D E L S
RADIAL VERSION
with trimmer
without trimmer
L
L
67
57
14.5
X
43
42
12
2
1.5
X1
34
24
3.5
X
CABLE VERS.
14.5
10
10
STABILITY LED
STABILITY LED
X1
OUTUPT LED
mm
CH.22 PLASTIC NUTS
TECHNICAL DATA
S51-PA AXIAL VERSION
10 ... 30 Vdc (limit values)
2 Vpp max.
30 mA max.
N.O.; PNP or NPN (short circuit protection)
100 mA max.
2 V max.
1 ms (4 ms mod.F00)
500 Hz (120 Hz mod.F00)
OUTPUT LED (YELLOW) mod.G00 excluded
POWER ON LED (GREEN) (mod.G00)
sensitivity trimmer (mod.B01/C01)
-25 ... 55 °C
-25 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 M 500 Vdc, between electronics and housing
A00: 0.1...3.5 m on R2
B01: 0.1...2.5 m on R2
C01: 1...40 cm
C10: 0...10 cm
F00/G00: 0...18 m
RED (660 nm) (mod.B01) / INFRARED (880 nm) (mod.A00/C01/C10/G00)
according EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
LIGHT mode (mod.C01/C10);
DARK mode (mod.A00/B01/F00)
PBT
PMMA
IP67
2 m cable  4 mm / M12 - 4 pole connector
75 g. max. cable vers. / 25 g. max. connector vers.
I I 3G EX nA II T6 ;
I I 3D EX tD A22 IP67 T85°C
Setting of S51-...A00/B01
M O D E L S
with trimmer
without trimmer
Position the sensor and reflector on opposite sides.
L
79
69
14.5
X
43
42
Moving the sensor both vertically and horizontally, determine the power
X1
46
36
on and off points of the yellow LED (OUT) and then mount the sensor in
the middle of the points defined.
B01 Model: Turn the sensitivity trimmer to the maximum position.
If necessary reduce sensitivity in order to detect very small targets. In
order to improve alignment, repeat the procedure detailed above whilst
progressively reducing the sensitivity.
25
10
CABLE VERS.
Setting of S51-...F00/G00
TRIMMER
10
Position the sensors on opposite sides.
Move the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
N°.2 Ø3.8
STABILITY LED
STABILITY LED
middle of the defined points.
OUTPUT LED
15
OUTPUT LED
Setting of S51-...C01
Turn the sensitivity trimmer to minimum: the yellow LED
is OFF.
Position the target to detect in front of the sensor.
Turn the sensitivity trimmer clockwise until the yellow
LED turns ON (Target detected state, pos.A).
Remove the target, the yellow LED turns OFF.
Turn the sensitivity trimmer clockwise until the yellow LED turns ON
(Background detected state, pos.B).
The trimmer reaches the maximum level if the background is not
detected.
S51-PR RADIAL VERSION
Turn the trimmer to the intermediate C position, between the two A and B
positions.
Setting of S51-...C10
The operating distance range of these sensors is factory preset: please
consider this feature when positioning.
The TEST+ and TEST- inputs can be used to inhibit the emitter and
verify that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted. The inputs activating voltage range is 10 ... 30
Vdc, whilst respecting the polarity.
The emission is switched off connecting TEST+ to Vdc and TEST- to
0V.
A00: 0.1...2.5 m on R2
B01: 0.1...2.0 m on R2
C01: 1...30 cm
C10: 0...8 cm
F00/G00: 0...15 m
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of
Sales for further details.
© 2007 - 2020 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without
limiting the rights under copyright, no part of this documentation may be reproduced, stored in
or introduced into a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many
countries, including the U.S.A. and the E.U. All other trademarks and brands are property of
their respective owners. Datalogic reserves the right to make modifications and improvements
without prior notification.
SETTING
A
C
MAX
MIN
TEST FUNCTION (S51-...G00)
EX-II-3-D T6
T6 (<85°C)
Temperature class:
Max. Power consumption:
900 mW at 30 Vdc
Max. Internal capacitance:
170 nF
Internal inductance:
negligible
For information about the disposal of Waste Electrical and Electronic
Equipment (WEEE), please refer to the website at www.datalogic.com.
826002973 Rev.E
B