DUUN 130001 Manuale di istruzioni - Pagina 8
Sfoglia online o scarica il pdf Manuale di istruzioni per Apparecchiature industriali DUUN 130001. DUUN 130001 9.
Service and maintenance
The hydraulic valves are set to 220 bar pressure. Changes to this are not permitted and any warranty
liability is void in such a case.
After 5 hours of use - check all screw connections.
Lubrication
Regularly check all lubrication points.
Article no. Quantity Designation
A
1
B
1
C
2
D
1
E
1
F
1
G
1
H
1/2
I
1
Grease nipple Upper assembly bolt
Grease nipple Rear cylinder rotation
Grease nipple Wheel fork storage
Grease nipple Front cylinder rotation
Grease nipple Lower assembly bolt
Grease nipple Front cylinder boom swing
Grease nipple Rear cylinder boom swing
Screw thread
Support wheel adjustment
Grease nipple Rotation bolt of csraper blade
8