RDM / DMX SERIAL LINK
OPTO-SPLITTER 1
8 PTB
X
PTB (Pluggable Terminal Block) connectors require bare wire installation into removable, screw-type terminal
connectors with tension sleeves. Depending on the application, cables can be unterminated on both ends, or have
a connector on one end to interface with other equipment (e.g. 5-Pin XLR). Each Input, Output, and Thru
connection point follows the same diagram for common, data positive and data negative conductors.
1—Strip the bare-end wire insulation back 7mm or roughly ¼ inch from cable end.
2—Insert bare wires into connector per the diagram below. Turn each connector set screw with a small flathead
screwdriver until tension spring is fully tightened onto the wire
3—To connect DMX signal input from an incoming console, use the DMX input in the right corner of the unit. To
pass the DMX signal to another device, use the Thru port.
4—Connect additional cables to each of the eight optically isolated PTB output ports in order to send data to any
DMX device, daisy-chaining between fixtures as necessary.