Dux proflo 125X136 Manuale d'uso - Pagina 2
Sfoglia online o scarica il pdf Manuale d'uso per Scaldabagno Dux proflo 125X136. Dux proflo 125X136 16. Electric storage water heaters
Anche per Dux proflo 125X136: Manuale d'uso (16 pagine)
WARNING – THIS APPLIANCE
MAY DELIVER WATER AT HIGH
TEMPERATURE. REFER TO THE
PLUMBING CODE OF AUSTRALIA
(PCA), LOCAL REQUIREMENTS
AND INSTALLATION INSTRUCTIONS
TO DETERMINE IF ADDITIONAL
DELIVERY TEMPERATURE CONTROL
IS REQUIRED.
WARNING – FOR CONTINUED
SAFETY OF THIS APPLIANCE IT
MUST BE INSTALLED, OPERATED
AND MAINTAINED IN ACCORDANCE
WITH THE MANUFACTURER'S
INSTRUCTIONS.
This water heater is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities,
or lack of experience and knowledge,
unless they have been given supervision
or instruction concerning use of the water
heater by a person responsible for their
safety.
Children should be supervised to ensure
they do not interfere with the water heater.
Ensure animals are supervised so they do
not interfere with the water heater.
DO NOT store chemicals or flammable
materials, or spray aerosols near this water
heater.
DO NOT modify this water heater.
DO NOT operate the water heater with any
panels or covers removed.
If the water heater is not used for two weeks
or more, a quantity of hydrogen (which is
highly flammable) may accumulate inside the
water heater tank.
i
Owner's Manual – Proflo Electric Storage Water Heaters
Important Safety Information
To dissipate this gas safely it is
recommended that a hot tap be turned on
for several minutes at a sink, basin or bath,
but not a dishwasher, clothes washer or
other appliance.
During this procedure there must be no
smoking, open flame or any other electrical
appliance operating nearby. If hydrogen is
discharged through the tap it will probably
make a sound similar to air escaping.
RELIEF VALVE:
The Pressure & Temperature Relief (PTR)
Valve must be installed directly into the RP½"
(DN15) socket marked "RELIEF VALVE".
The PTR Valve rating is 1,400 kPa and
10 kW on 80L, 125L and 160L capacities.
The PTR Valve rating is 1,000 kPa and
10 kW on 135L, 180L, 250L, 300L, 315L
and 400L capacities.
The valve must not be tampered with or
removed. The water heater must not be
operated unless this valve is fitted and in
working order.
The drain line from the PTR Valve must
be installed in a continuously downward
direction in a frost free environment.
The PTR Valve is to be operated regularly
to remove lime deposits and to verify it is
not blocked. The drain line fitted to the PTR
Valve must be left open to the atmosphere.
DANGER – FAILURE TO OPERATE
THE PTR VALVE EASING LEVER AT
LEAST ONCE EVERY SIX MONTHS
MAY RESULT IN THE WATER HEATER
EXPLODING. CONTINUOUS LEAKAGE
OF WATER FROM THE VALVE MAY
INDICATE A PROBLEM WITH THE
WATER HEATER.
H0421
0421
Rev. R