The average total body water percentage range for healthy men is between 50 – 65%.
The equivalent value for women is approximately 45 – 60% due to the higher body fat
content. About two third of the total body water is stored in the cells and is therefore
called intra cellular. The other third of the total body water is extra cellular body water.
For men is the normal range of body mass index between 20 and 25, for women 19 to
24. When people in the second half of life a body mass index to 26 is considered as still
normal.
Women
AGE
Body Fat
slim
normal
10-16
<18%
18-28%
17-39
<20%
20-32%
40-55
<23%
23-35%
56-85
<24%
24-36%
AGE
Body Fat
slim
normal
10-16
<10%
10-18%
17-39
<12%
12-20%
40-55
<13%
13-21%
56-85
<14%
14-22%
There are no validated standards for muscle mass.
7. Error Messages
"EEEE"
=
Overload display – The 150 kg maximum capacity of the scales has
been exceeded. Immediately remove the load from the scales;
otherwise, the load cell could be damaged.
"LO"
=
Indication that the battery is flat – Please replace the battery with one
CR2032.
"Errl"
=
Low fat indication - Under 5% body fat, not possible to indicate.
"ErrH"
=
High fat indication – Over 75% body fat, not possible to indicate.
"▪ ▪ ▪ ▪"
=
Incorrect weighing- / measuring process - For example, the scales
is placed unstable or you do not remain stationary on the weighing
platform.
Body Water
slightly
overweight
overweight
normal
29-35%
>35%
57-67%
33-38%
>38%
47-57%
36-41%
>41%
42-52%
37-42%
>42%
37-47%
Men
Body Water
slightly
overweight
overweight
normal
19-23%
>23%
58-72%
21-25%
>25%
53-67%
22-26%
>26%
47-61%
23-27%
>27%
42-56%
6
their hydration level. Retaining fluid may cause the weight to fluctuate day-to-day. This will
also affect the body fat percentage readings. If the hydration level is high, the body fat
percentage is slightly less – a less hydration level means the body fat percentage is slightly
higher. There is no healthy risk for pregnancy. The body analyzer is absolute safe for the
mother and her unborn baby. However, due to the changes in water content in the
mother's body, the readings should not be interpreted as completely accurate.
ADE Germany takes no responsibility for any damages or losses caused by the use of this
body analyzer scales or for Third Party claims. This product is exclusive intended for
private use. This product is not designed for commercial or professional use in hospitals or
other medical facilities.
3. Commissioning
Safety guideline s: The appliance is not intended for use by persons (including children)
with reduced physical, sensory, or mental capabilities, or lack of experience and
knowledge, unless a person responsible for their safety has given them supervision or
instruction concerning use of the appliance. Children should be supervised to ensure that
they do not play with the appliance.
Not suitable for persons with electronic implants (heart
pacemaker, etc.).
Place the scales on a plane, firm surface (tiles, hardwood
flooring, etc.) to avoid a wrong measurement on carpeted
floor
Attention - Hazard of slips! Do not stand on the scales with
wet feet or on a slippery surface of the weighing platform.
Ensure that no object fall onto the scales, the glass surface
is breakable.
Only use a damp cloth to clean the scales. Never use
solvents or abrasive cleanings. Do not submerge the scales
under water.
Preparation:
Open the lid of the battery compartment on the bottom of the scales and insert the
supplied battery (one CR2032). Please ensure the correct polarity of the battery (+/-).
There is a little push button left beside the battery compartment on the bottom of the
scales for country specific settings with the option to switch from KG = kilogram to LB =
pound. Please ensure that the scales are set to the appropriate units of weight for you.