Electric Lock Connection

Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than
250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
connect one lock
1 2 3
Connect one lock
Jumper position in
BUS
PL
S1+
EB
*
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. Setup the Unlock Mode of Monitor for different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1
2-3
S2+
S-
LOCK
connect two locks
1 2 3
Connect two locks
Jumper position in
2-3
BUS
PL
S1+
1
ST
EB
*
2
EB
nd
*
S2+
S-
2
nd
LOCK
1
ST
LOCK