Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Bruciatore Auscrown Y018NGWF-S. Auscrown Y018NGWF-S 11. Duckbill stockpot burner with flame failure safety device

Gas Type and Gas Pressure
Do not use any other gas type except the one specified on the data label.
For LP Gas Model (Supplied with regulator type 73-1-8 AGA 3884 and Hose TPA type APH801 6356)
This model of appliance is suitable for use with LP gas and are set to operate under gas pressure of 2.75kPa.
*The LP gas regulator and hose supplied are for outdoor installations only. Indoor installations must
be installed in accordance with the requirements of AS/NZS5601.1.
Indoor installations must be installed in accordance with the requirements of AS/NZS5601.1, Local
State and Territory regulations, municipal building codes, and any other relevant statutory
regulations.
For Natural Gas Model (Supplied with Bromic type 980L regulator AGA 5862)
This model of appliance is only suitable for use with natural gas and are set to operate under gas pressure of
0.90kPa.
WARNING! It is hazardous to attempt to use other types of gas with this appliance.
The Gas Inlet is located for model Y028NGWF-S/Y028LPWF-S 300mm up from the base and 25mm in
from the RH side leg. For model Y018NGWF-S/Y018LPWF-S the gas inlet is located 260mm up from
the base and in line with the RH leg side.
Gas Cylinder (For LP Gas Model only)
Only cylinders which comply with AS2030.1 should be used. The appliance is suitable for use with gas
cylinders of 3.9 kg or greater.
The gas cylinder should not be dropped or handled roughly! If the appliance is not in use, the cylinder must
be disconnected. Replace the protective cap on the cylinder after disconnecting the cylinder from the stove.
WARNING! It may hazardous to use a damaged or dented gas cylinder.
Cylinders must be stored outdoors in an upright position and out of the reach of children. The cylinder must
never be stored under direct sunlight or where temperatures can reach over 50C. Do not store the cylinder
near flames, pilot lights or other sources of ignition. DO NOT SMOKE around the cylinders.
WARNING! It may hazardous to store gas cylinder in an enclosed place.
Exchanging of the gas cylinder
Ensure the valve on the cylinder is closed. Remove the hose assembly. Connect in reverse order and check
for gas leakage at all joints with soapy water.
Gas Hose Assembly
Use only the hose assembly supplied with the appliance. Use only a gas hose that complies with
AS/NZS1869. The appliance requires a 'Class B' Gas hose. The hose should be secured to the regulator
and the appliance with spanner. Use the hose with the right threads, DO NOT use adaptors. Inspect the
hose assembly before each use of the appliance.
The life expectancy of the hose is estimated at 5 years. It is recommended that the hose is changed every 5
years.
The use of the wrong hose is unsafe. Always check that you have the correct items before operating the
appliance.
WARNING! It may hazardous to use the wrong type of hose.
The length of the hose must not excess 1.8 metres (maximum). Worn or damaged hose must be replaced if
there is evidence of excessive abrasion or wear. A replacement hose is supplied by Austcrown, refer to
contact detail. Ensure that the hose is not obstructed, kinked, or in contact with any part of the appliance
other than at its connection.
WARNING! It may hazardous to use a damaged hose.
Regulator
Use only the gas regulator supplied with the appliance which complies with AS4618. The appliance must be
used with a LOW pressure regulator with output pressure of 2.75kPa for LP gas and 0.90kPa for Natural Gas.
Use a regulator with the right threads.
For Propane Gas Model:
AUSCROWN TPA7010 AGA 5212
Outlet Pressure: 2.75kPa
Flow Capacity: 3kg/hr
Inlet Fitting: CGA-510 POL with Soft Nose
Outlet Fitting: 3/8" BSPF Thread
AC-R2-001
For Natural Gas Model: Bromic 980L, AGA 5862
Outlet Pressure: 0.90kPa
Flow Capacity: 2 M
3
/hr (For Y018NGWF-S)
Flow Capacity:
3 M
3
/hr (For Y028NGWF-S)
Inlet Fitting: ½" BSPF Thread