Datasensor SE-S 1500 Manuale - Pagina 3
Sfoglia online o scarica il pdf Manuale per Sensori di sicurezza Datasensor SE-S 1500. Datasensor SE-S 1500 11. Accessories for safety devices
SE-LP SERIES
NOTES AND WARNINGS
NOTE: The SE-SP laser pointer uses a red laser light
beam that can be potentially dangerous to the
human eye.
Do not stare directly at the light beam.
The laser pointer is powered by three 1.5 V LR-44 type
batteries.
Battery replacement:
- Unscrew the back lid using the thin pin included in the lid slot.
- Remove the flat batteries.
- Insert the three new batteries placing the negative pole first.
- Screw back the lid.
NOTE: Avoid keeping the device powered a long time.
38.02
14
100.8
93.8
Laser pointer
DIMENSIONS
Ø44.8
26.4
47
65.55
INSTRUCTIONS FOR USE
•
Install the emitting and receiving units of the SE series safety device in the defined positions
(refer to MECHANICAL MOUNTING chapter of the safety light curtain instructions manual). The
use of the SE-S floor stands are recommended, verifying that they are firmly fixed and that their
axis is perpendicular to the floor.
•
Insert the SE-LP laser pointer in the upper part of the emitting unit using one of the two side
slots of the profile (refer to drawing).
As shown, the laser pointer is positioned inside the detection
field of the safety device and thus inhibits the functioning
during the alignment phase. In case of safety devices for
access control, this inconvenience can be avoided by
positioning the laser pointer in a zone not affected by optic
groups. The device functioning is thus not inhibited and the
alignment results can be observed directly on the receiving
unit's signalling LEDs.
•
Power the laser pointer rotating the front ring nut.
Orientate the emitting unit in order that the laser beam hits the
receiving unit at the same height of the pointer.
NOTE: The holes of the fixing bracket or the orientable supports available as accessories
can be used to orientate the unit, allowing angle adjustment along the vertical unit
axis. If necessary the inclination of the floor stand can be changed by simply
mounting washers under the base.
•
Repeat this procedure inserting the pointer in the lower part of the emitting unit; if necessary
repeat this procedure unit the desired result is obtained.
•
Insert the laser pointer in the upper part of the receiving unit and orient this unit in order that the
laser beam hits the emitting unit as indicated.
•
Repeat this procedure inserting the laser pointer in the lower part of the receiving unit.
After this operation switch on the safety device and verify the correct alignment.
NOTE: The laser pointer, due to mechanical tolerance problems in the matching with the
light curtain housing, provides an approximate indication and hence small
corrections may be necessary in the unit alignment, following the ALIGNMENT
PROCEDURE described in the safety light curtain instructions manual.
•
Proceed with the definitive mounting of the emitting and receiving units.
856000400 Rev.00