Aussie Pumps QP-60TDK/D1105 Manuale delle operazioni e delle parti di ricambio - Pagina 18
Sfoglia online o scarica il pdf Manuale delle operazioni e delle parti di ricambio per Pompa dell'acqua Aussie Pumps QP-60TDK/D1105. Aussie Pumps QP-60TDK/D1105 20. Trash pump
Figure 2 below shows a typical application using the
trash pump. Please note that this pump is intended for
the removal of clean water and water containing some
debris and solids.
Maximum size of solids should not exceed 2 inches (51
mm) in diameter.
DO NOT set strainer on bottom of water bed. Placing the
strainer above the water bed will prevent the pump from
drawing in excessive amounts of sand and foreign
debris.
TERMS TO KNOW
The following terms are usually used when referring to
lift or head:
1.
Static Suction Lift - The vertical distance from
PAGE 18
QP60TDK SERIES TRASH PUMP• OPERATION AND PARTS MANUAL — REV. #0
the water line to the centre of the impeller.
2.
Static Discharge Head - The vertical distance from
the discharge outlet to the point of discharge or
liquid level when discharging into the bottom of a
water tank.
3.
Dynamic Suction Head - The static suction lift plus
the friction In the suction line. Also referred to as
total suction head.
4.
Dynamic Discharge Head-The static discharge
head plus the friction in the discharge line. Also
referred to as total discharge.
5.
Total Dynamic Head - The Dynamic Head Suction
Head plus the Dynamic Discharge Head. Also
referred to as total head.