Warning: check nozzles and replace of worn
If pressure drops off, check nozzle for wear. Nozzles should be replaced on a regular basis (every month for
machines in regular use, every 3 months for machines used intermittently. Using the machine with the
incorrect nozzle size or worn nozzle will void warranty and can be dangerous to the operator.
CARE & MAINTENANCE:
AFTER EACH USE
If cleaning agents have been mixed with the incoming
water, it is essential to flush the machine with clean
water after use.
If there is a danger of freezing anti-freeze should be
mixed with the flush water or the machine must be
completely drained.
After the final flush stop the machine. DO NOT allow
the machine to idle for more than 15 seconds. This is
particularly important when there is a danger of
freezing. Do not run for longer without water supply.
STORAGE
Store the washer in an upright position, preferably
drained of water if there is a danger of freezing (or fill
with anti-freeze).
PUMP CRANKCASE LUBRICATION
Proper pressure washer pump crankcase lubrication
will help extend the working life of the machine.
Follow these important guidelines. We recommend
keeping a simple service log book.
Change oil in pump after initial 50 hour run-in
period. (SAE 75W-90)
Change pump oil every 3 months, use high quality
oil. (SAE 75W-90)
Pump oil level can be checked with the dip stick
under the breather cap or by viewing the oil sight
gauge where fitted. The oil level is correct if level is
in the centre of the gauge. If oil level is low, fill to
correct level with recommended oil (SAE 75W-90).
DO NOT OVERFILL CRANKCASE!
8
Aussie AB Scud Cadet Series ... Operation & Maintenance Manual
PREVENTATIVE MAINTENANCE
Keep filter in supply hose connection clean, rinse
regularly.
Use correct size nozzles for machine and replace
when worn, check serial tag for correct size.
Drain water from pressure hoses, gun/lance
assembly and accessories after use.
Protect pump from freezing. Failure to remove
water from the pump in freezing temperatures will
result in damaged pump manifold.
DO NOT tamper with unloader valve adjustment
or alter engine speed.
DO NOT siphon chemicals through the pump, it is
designed for water only.
Incoming water supply must not exceed 60°C,
otherwise pumps seal damage could result
Follow engine manufacturers guidelines for engine
maintenance. (see engine manual)
March 2018