8. SPECIFICATION
MODEL
Max Recommended PV Power (Wp)
Vmax PV (absolute maximum) (Vdc)
PV Input Operating Voltage Range (Vdc)
INPUT(DC)
Maximum Operating PV Input Current (Adc)
MPPT Tracking Accuracy
Isc PV (absolute maximum) (Adc)
Maximum Inverter Backfeed Current to the Array (Adc)
Rated AC Output Power (W)
Nominal Power Grid Voltage (Vac)
Nominal Output Current (Aac)
Current (inrush) (Peak and Duration)
OUTPUT(AC)
Nominal Frequency (Hz)
Power Factor
Maximum Output Fault Current (Aac)
Maximum Output Overcurrent Protection (Aac)
SYSTEM
CEC Efficiency
Night Time Tare Loss (W)
EFFICIENCY
Over/Under Voltage Protection
Over/Under Frequency Protection
Anti-Islanding Protection
Over Current Protection
PROTECTION
Reverse DC Polarity Protection
FUNCTIONS
Overload Protection
Ground Fault Detection
Protective Class
IP Rating
Environment Temperature
Display
OTHER
Communications
PARAMETERS
Dimension (D-W-H mm)
Weight(Kg)
14
AU-1P6002G-230-EU
480x 2
60
22-55
28
>99.5%
36
0
580
230
2.5
24A, 15us
50
>0.99
(at rated power)
4.4A peak
10
96.9%
0.11
Yes
Yes
Yes
Yes
Yes
Yes
Integrated
Integrated
I
IP66 / IP67
-40℃ ~+65℃
LED LIGHT
POWERLINE/WIFI
277*132*50
2.9
MODEL
Max Recommended PV Power (Wp)
Vmax PV (absolute maximum) (Vdc)
PV Input Operating Voltage Range (Vdc)
INPUT(DC)
Maximum Operating PV Input Current (Adc)
MPPT Tracking Accuracy
Isc PV (absolute maximum) (Adc)
Maximum Inverter Backfeed Current to the Array (Adc)
Rated AC Output Power (W)
Nominal Power Grid Voltage (Vac)
Nominal Output Current (Aac)
Current (inrush) (Peak and Duration)
OUTPUT(AC)
Nominal Frequency (Hz)
Power Factor
Maximum Output Fault Current (Aac)
Maximum Output Overcurrent Protection (Aac)
SYSTEM
CEC Efficiency
Night Time Tare Loss (W)
EFFICIENCY
Over/Under Voltage Protection
Over/Under Frequency Protection
Anti-Islanding Protection
Over Current Protection
PROTECTION
Reverse DC Polarity Protection
FUNCTIONS
Overload Protection
Ground Fault Detection
Protective Class
IP Rating
Environment Temperature
Display
OTHER
Communications
PARAMETERS
Dimension (D-W-H mm)
Weight(Kg)
AU-1P8002G-230-EU
600x 2
60
22-55
34
>99.5%
40
0
800
230
3.48
9.4A, 15us
50
>0.99
(at rated power)
9.6A peak
10
96.9%
0.11
Yes
Yes
Yes
Yes
Yes
Yes
Integrated
Integrat
I
IP66 / IP67
-40℃ ~+65℃
LED LIGHT
POWERLINE/WIFI
268*250*42
2.9
15