AUSTART ATS83-2 Manuale di installazione e manutenzione - Pagina 5
Sfoglia online o scarica il pdf Manuale di installazione e manutenzione per Controllore AUSTART ATS83-2. AUSTART ATS83-2 16. Turbine starter
INSTALLING THE STARTER AND PIPEWORK
Refer to the Starter Installation Schematic drawing on page 6.
1. The air supply line should ideally exit from
the top or side of the air receiver.
CAUTION
Do not connect air supply line to the bottom
of the air receiver.
contaminants collect at the receiver bottom
and
can
damage
internals
if
allowed
Periodically drain moisture from the air
receiver using a drain valve connected at the
receiver bottom.
2. Install a 100 mesh 'Y' strainer. A 'Y' strainer
installed before the relay valve will provide
protection to the valve and AUSTART
starter from contaminants that may have
accumulated in the air receiver. Fitting of
an inline 'Y' strainer (as described above)
is also required to ensure the AUSTART
starter is covered by our product warranty.
NOTICE
Ensure the inlet side of the 'Y' strainer faces
the receiver ie the direction arrow points
away from the receiver.
3. Install AR1000 relay valve directly onto the
air starter motor inlet port with the two
screws provided. Ensure to also fit the
sealing
o'ring
adaptor flange is available for remote
mounting if required.
NOTICE
Ensure the inlet side of the relay valve
connects to the exit side of the 'Y' strainer.
Moisture and system
the
AUSTART
starter
to
pass
through.
provided.
An
optional
4. Mount the starter control button SC25 onto
the vehicle dash-board or appropriate
control panel and connect to the air
receiver using a minimum of 1/4" (6mm)
line.
Ensure the inlet side of the starter control
button connects to the line from the receiver.
Any safety 'switches' should be installed in
this line between the starter control button
and the air receiver.
5. Determine the practicality of running the
1"air supply hose or pipe from the exit of
the 'Y' strainer to the inlet of the AUSTART
starter
after
mounted. It may be easier to fit the hose
before the AUSTART starter is mounted in
position.
6. Once the AUSTART starter is mounted, fit
the remaining 1/4" (6mm) control lines
from the AUSTART starter to the starter
control button and relay valve respectively
(refer page 6).
7. Make all hose or pipe connections leak
proof using a suitable thread sealant.
8. Once the connections have been made,
pressurise the system and check for leaks
using 'soapy' water or similar solution.
5
NOTICE
the
AUSTART
starter
is