NOTE:
• Make sure the filter is securely locked. Otherwise, it could loosen and
cause damage to unit.
• When the activated carbon filters are attached, the suction power will
be lowered.
• The charcoal filter cannot be washed or recycled. It should be changed
at three or six months according to the amount of use the hood
receives.
• Replacements are available from the stockist from whom you
purchased the hood.
BULB REPLACEMENT
Important :
Changing the light:
• Make sure the cooker hood is unplugged or turn OFF breaker.
• Loose the 3pcs screws of the switch panel top.
• Open the cover plate.
• Open the terminal box.
• Dismantle the connection terminal of the lamp.
• Use a straight screwdriver to slightly prize up the LED light and
carefully take out the lamp to replace.
•
ILCOS D code for this lamp is: DSR-1.5/65-S-64
– LED modules– round lamp
– Max wattage: 1.5 W
– Voltage range: DC 12V
– Dimensions:
16
The bulb must be replaced by a competent
person.
Always switch off the electricity supply before
carrying out any operations on the appliance.
When handling bulb, make sure it is
completely cool down before any direct
contact to hands.
When handling globes hold with a cloth or
gloves to ensure perspiration does not come
in contact with the globe as this can reduce
the life of the globe.