Austria Email KRU 1020 Manuale di istruzioni per l'uso - Pagina 8

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Scaldabagno Austria Email KRU 1020. Austria Email KRU 1020 14. 5/10l

Austria Email KRU 1020 Manuale di istruzioni per l'uso

ELECTRICAL CONNECTION

Before the electrical connection is made, the storage tank must be completely filled
with water!
CAUTION: You must disconnect the power before any intervention in the water
heater!
The electrical connection must be made according to the valid provisions and standards.
The water heater is connected to the mains via the connection cable.
In some cases, it is necessary to replace the installed connection cable with a new cable.
To do this, the plastic casing of the water heater must be removed. In order to remove this,
first remove the plate on the front of the casing by carefully inserting a spanner in the slot
between the plate and protective cover, first at the thermostat knob and then opposite from
the knob. If the plate is loosened on both sides, it can be removed by hand. Then remove
the thermostat knob and remove the fastening screw below the knob. Last unscrew all four
fastening screws and the casing can be removed. Now the installed connecting cable can
be removed from the connecting terminal and replaced with a new cable.
It should be noted that in case of failure (body circuit / leakage) it can trigger the RDC
(Residual Current Device) come. This means that all electrical equipment is energized in
this circuit.
Therefore, a separate RCD must be provided for the operation of the small memory should
other electrical equipment to be used, in which an uninterruptible power supply must be
guaranteed, as Freezers, refrigerators for medicines, emergency lighting, etc.
Legend to symbols:
1 - Thermostat
2 - Heating fuse
3 - Heating rod
4 - Control lamp
5 - Connecting terminal
L - Phase conductor
N - Neutral conductor
- Protective conductor
Diagram for connection to the electrical line
8