Filling the Syringe
1. Remove the Cap from the Luer Tip.
2. Load the required Syringe size by threading it onto the Luer Tip (Figure 10).
3. Make sure all hands and fingers are clear of the machine. Press and release the Foot Switch to
activate the filling cycle.
4. The system will automatically shut off when the Syringe Piston or Syringe Plunger touches the Syringe
Fill Stop.
NOTE: Use the Cylinder Retract Switch as an E-Stop if the machine does not stop automatically.
5. Remove the Syringe from the Luer Tip.
6. Cap the Syringe Tip and the Syringe End as needed.
7. Repeat above steps 2 through 6 for each additional syringe needed.
Model 830 Valve Adjustments
The Model 830 Valve highlights a suck-back feature to prevent oozing and dripping between syringes.
Depending on the type of fluids used, the suck-back feature will require adjustment. Batch-to-batch
adjustment is recommended. If material drips, suck-back should be increased. If there are air bubbles in the
syringe, decrease the amount of suck-back.
Adjusting Suck-Back Position (Front)
The Adjustment Screw is located on the top face of the valve. To increase suck-back, loosen the adjustment
screw counter-clockwise. To decrease suck-back, tighten the adjustment screw clockwise (
Figure 11).
Increase Suck-Back (Counter-Clockwise)
Increase Suck-Back (Counter-Clockwise)
Figure 11. Suck-Back Adjustment Screw
Tridak® Model 1001 Syringe Filling System User Guide
Decrease Suck-Back (Clockwise)
Decrease Suck-Back (Clockwise)
17