dymax Tridak 1001 Manuale d'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature industriali dymax Tridak 1001. dymax Tridak 1001 20. Syringe filling system

6
Tridak® Model 1001 Syringe Filling System User Guide

Description of Main Components

The main components in the Model 1001 Syringe Filling System include:
Air Regulator
1.
air precision regulator includes:
a.
Pressure gauge that displays the pressure in the fluid reservoir. A 0- to 100-psi (0- to
6.9-bar) pressure gauge is installed on the air regulator.
b. Pressure control knob that enables adjustment of the pressure of the air entering the
reservoir. 5-60 psi recommended for most applications.
Compressed Air Line
2.
use.
Model 830 Valve
3.
reservoir. This valve features suck-back, allowing drip-free dispensing from fill-to-fill.
Disposable Fluid Path
4.
to syringes. It is constructed of black, light-blocking polyethylene tubing compatible with many types
of commercial and medical fluids.
Material Reservoir Retainer
5.
retainers accept cartridge reservoirs. Reservoir tanks accept bottle and pail reservoirs.
Material Reservoir Support
6.
support.
Material Reservoir Pressure Supply
7.
material reservoir retainer. The air regulator controls the pressure supplied to the material reservoir.
Foot Switch
8.
depressed, the machine will automatically cycle and shut off once the fill switch is tripped.
Adjustable Syringe Support
9.
line with the fill stop switch and the Luer or Oral tip fitting.
Fill Stop
10.
– The air-operated switch that controls the machine shut off once target fill volume is
achieved.
Cylinder Retract Switch
11.
stop the machine operation at any time in the cycle.
Quick Clamp Release
12.
Valve. The clamp allows for quick and easy material line changeover.
– The air regulator enables precise control of the air pressure in the fluid reservoir. The
– The air line consists of blue polyurethane tubing designed for compressed air
– A disposable fluid path valve used to dispense material from the material
– The fill tube and fittings used to deliver fluid material from bulk cartridges
– The reservoir retainers and tanks hold fluid reservoirs. Reservoir
– The adjustable vertical support is used to mount material reservoir
– The air supply line that pressurizes the material in the
– Depression of the foot switch initiates the machine fill cycle. Once the foot switch is
– The support is used to ensure the syringe is supported to remain in
– Manual retraction switch for fill stop cylinder. This switch can be used to
– The clamp mechanism is used to hold the material line in the Model 830