Sfoglia online o scarica il pdf Manuale d'uso per Unità di controllo dymax 828. dymax 828 16. Disposable fluid path dispensing valve
Adjusting Suck Back
To adjust the suck back of the Model 828 valve, turn the Suck-Back Adjustment Screw
(Figure 5, B) clockwise to decrease suck back or counterclockwise to increase suck
back.
Figure 5.
Adjustment Controls
B – Suck-Back
Adjustment Screw
Figure 6. Piston Stop Screw
Suck-Back Piston Stop-
Screw: Preset to Close
Tube 50%
1 1
A – Pinch-Piston Flow
Adjustment Screw
Pinch-Piston Stop-Screw:
to Stop Flow; Do Not Over
Pinch