powers are connected, the relay is in OPEN mode. If only one of the power sources is
connected, the relay changes to SHORT mode. This relay will only work with P1 and P2. It is
independent from P3.
Power connecting procedure:
STEP 1 – Pull out 6 pin terminal block.
STEP 2 – Connect wire to P1+, P1-, P2+, P2-, and the neutral wire to the ground screw.
STEP 3– Plug connected 6 pin terminal block back into place.
Or, Connect the P3 power DIN from external power adapter.
WARNING -- Always SHUT OFF power source to connect power wire.
WARNING -- Always ground the power source to maintain a clean power input. Cheaply
made power supplies create too much noise and will cause the power input to fluctuate
when connected to this unit. To avoid this, always ground the power source to maintain a
clean power input.
4