Dymond M-18A9 Manuale d'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature di prova Dymond M-18A9. Dymond M-18A9 12. Gold tester

"Yellow Gold" or "White Gold" does not light.
Problem:
Low Battery light is on.
Replace batteries observing the polarity on the holder.
Cause/Solution:
Problem:
The testing light does not light.
Clean test Gold in area to be tested.
Cause/Solution:
Alligator clip not connected to test Gold.
Reference Gold coated.
Thoroughly clean the gold well.
Problem:
18 Karat indication for all tests.
Test Gold removed before testing light goes out.
Cause/Solution:
Test Gold or clip being shorted to reference Gold at bottom
of well.
Thoroughly clean the gold well.
"NOT GOLD" reading for all tests.
Problem:
Alligator clip in liquid during test.
Cause/Solution:
TROUBLE SHOOTING GUIDE
10