GRDIAN Charger Plus Manuale d'uso - Pagina 14

Sfoglia online o scarica il pdf Manuale d'uso per Apparecchiature di prova GRDIAN Charger Plus. GRDIAN Charger Plus 18. Hardwire kit

VOLTAGE PROTECTION SETTING

The Charger Plus will cut off power output to the dash cam when the voltage drops below the set
threshold. Set the voltage setting based on your car's battery status.
HOW DO I SETUP A VALUE THAT FITS MY VEHICLE?
1. Make sure your vehicle's electrical status is OFF. Check the voltage value of your vehicle by
using your multimeter. Set the multimeter to 20 DCV. Use the black lead to touch your
ground point and place the
2. Set the Voltage Protection Setting based on your findings. For example: If the multimeter
detects 12.2V, you may set the voltage setting to 12-11.8V or at least 0.2V lower.
NOTE: Make sure you set the correct voltage setting or your dash cam may keep rebooting. Once
installed, check the camera if it is operating normally. If your dash cam keeps rebooting you may
need to set a lower threshold. If you continue to have issues, have your battery checked by a
professional.
11
red
lead on your fuse. Note the voltage.