Dawson DCM201A Manuale d'uso - Pagina 7
Sfoglia online o scarica il pdf Manuale d'uso per Strumenti di misura Dawson DCM201A. Dawson DCM201A 17. Digital clamp meter
Specifications
The Meter should be calibrated annually between 18℃ ~ 28℃ and
a relative humidity less than 75%.
1.3.1 General Specifications
Manual and Auto Mode
Power Overload Protection
Maximum Voltage Between Circuit and Ground: 1000V DC or
750V AC
Maximum Working Height: 2000m
Display: LCD
Maximum Display Number: 5999
Auto Polarity Indication, '-'Indicates Negative
Overload Indication: '0L' Or '-0L'
Sampling Frequency: 3 Times / Sec
Units Display: Display Functions and Units.
Auto Power Off: 15 Minutes
Input Power : 9V DC
Battery Type: 9V NEDA 1604, 6F22
Low Battery Indication: LCD Display"
Working Environment Temperature: 18℃ ~28℃
Storage Temperature:-10℃ ~50℃
Size:238×92×50mm
Weight: ~420g (Include Battery)
"
Technical Specifications
Temperature: 235℃ Relative Humidity: <75%
AC Current
Range
Resolution
60A
0.01A
600A
0.1A
1000A
1A
Maximum Input Current: 1000A AC or 1000A DC
Frequency Range @ 0~600A : 40 ~ 400Hz ;
@ 600A~1000A : 40 ~60Hz
DC Voltage
Range
Resolution
60mV
0.01mV
600mV
0.1mV
6V
0.001V
60V
0.01V
600
0.1V
1000V
1V
Input Resistance: 10M
Maximum Input Voltage: 750V AC (RMS) or 1000V DC
Accuracy
(2.5% + 8 Counts)
Accuracy
(0.5% + 5 Counts)
(0.8% + 4 Counts)
7