Dyna-Glo LPFA40WH Manuale d'uso e istruzioni per l'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale d'uso e istruzioni per l'uso per Riscaldatore a gas Dyna-Glo LPFA40WH. Dyna-Glo LPFA40WH 18. Propane construction heater

Dyna-Glo LPFA40WH Manuale d'uso e istruzioni per l'uso

TROUBLESHOOTING:

PROBLEM
1. Control   d ial   i s   o ff   a nd   u nit   i s
clicking/4cking
2. The   u nit   i s   4 cking/clicking  
while   t he   h eater   i s   l it.
3. Fan   d oes   n ot   t urn   w hen
electrical   c onnec4on   i s   m ade.
4. Heater   w ill   n ot   fi re.
5. Heater   q uits   w hile
running.
Always be sure to follow proper maintenance procedures, by cleaning the heater once per
month during regular usage, and check spark gap at least once per season.
10
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING
POSSIBLE   C AUSE
1. This   h eater   u ses   a   c on4nuous   s park
igni4on   s ystem.   T his   u nit   w ill   c on4nue
to   m ake   a   c licking/4cking   s ound   a t   a ll
4mes   b efore   i gni4on,   a Aer   i gni4on
and   d uring   o pera4on,   r egardless   o f
valve   k nob   p osi4oning.
1. This   h eater   u ses   a   c on4nuous   s park
igni4on   s ystem.   T his   u nit   w ill   c on4nue
to   m ake   a   c licking/4cking   s ound   a t   a ll
4mes   b efore   i gni4on,   a Aer   i gni4on
and   d uring   o pera4on,   r egardless   o f
valve   k nob   p osi4oning.
1. No   e lectric   p ower   t o   h eater.
2. Fan   b lade   c ontacts   i nside   o f   h eater   h ousing.
3. Fan   b lade(s)   b ent
4. Fan   m otor   d efec4ve.
1. No   s park   a t   i gnitor.
2. Improper   s park   g ap.
3. Bad   e lectrode.
1. Internal   t emperature   t oo   h igh   c ausing   l imit  
switch   t o   s hut   d own   o pera4on.
2. Damaged   C ontrol   V alve.
3. Dust   o r   d ebris   b uild-­‐up   i nside   o f   h eater.
CORRECTIVE   A CTION
1. No   c orrec4ve   a c4on   i s   n eeded.
1. No   c orrec4ve   a c4on   i s   n eeded.
1. Check   c urrent   t o   e lectric   o utlet.   I f   v oltage   i s   c orrect,
check   p ower   c ord   a nd   e xtension   c ord   f or
2. Be   s ure   t hat   h ousing   i s   n ot   d amaged.   M ake   s ure
there   a re   n o   o bstruc4ons   t o   t he   f an.
3. Straighten   b lade(s)   t o   m atch   o thers.
4. Replace   m otor.
1. Check   i gnitor   w ire.   R e-­‐aQach   o r   4 ghten   i f   l oose.
Check   S park   m odule.   R eplace   i f   n ecessary.
2. Set   g ap   ( See   s pecifica4ons   f or   g ap).  
3. Replace   S park   P lug.
1. If   t he   h eaters   o utput   i s   r estricted,   i nternal   t emperature
becomes   t oo   h igh.   M ove   h eater   a way   f rom
any   o bstruc4ons.
2. Replace   C ontrol   V alve.
3. Clean   i nside   o f   h eater.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!