Dyna-Glo Professional RMC-FA125DGP-01 Manuale d'uso e istruzioni per l'uso - Pagina 12
Sfoglia online o scarica il pdf Manuale d'uso e istruzioni per l'uso per Riscaldatore a gas Dyna-Glo Professional RMC-FA125DGP-01. Dyna-Glo Professional RMC-FA125DGP-01 20. Propane construction heater
TROUBLESHOOTING:
PROBLEM
1. Control
d ial
i s
o ff
a nd
u nit
i s
clicking/4cking
2. The
u nit
i s
4 cking/clicking
while
t he
h eater
i s
l it.
3. Fan
d oes
n ot
t urn
w hen
electrical
c onnec4on
i s
m ade.
4. Heater
w ill
n ot
fi re.
5. Heater
q uits
w hile
running.
Always be sure to follow proper maintenance procedures, by cleaning the heater once per
month during regular usage, and check spark gap at least once per season.
11
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING
POSSIBLE
C AUSE
1. This
h eater
u ses
a
c on4nuous
s park
igni4on
s ystem.
T his
u nit
w ill
c on4nue
to
m ake
a
c licking/4cking
s ound
a t
a ll
4mes
b efore
i gni4on,
a Aer
i gni4on
and
d uring
o pera4on,
r egardless
o f
valve
k nob
p osi4oning.
1. This
h eater
u ses
a
c on4nuous
s park
igni4on
s ystem.
T his
u nit
w ill
c on4nue
to
m ake
a
c licking/4cking
s ound
a t
a ll
4mes
b efore
i gni4on,
a Aer
i gni4on
and
d uring
o pera4on,
r egardless
o f
valve
k nob
p osi4oning.
1. No
e lectric
p ower
t o
h eater.
2. Fan
b lade
c ontacts
i nside
o f
h eater
h ousing.
3. Fan
b lade(s)
b ent
4. Fan
m otor
d efec4ve.
1. No
s park
a t
i gnitor.
2. Improper
s park
g ap.
3. Bad
e lectrode.
1. Internal
t emperature
t oo
h igh
c ausing
l imit
switch
t o
s hut
d own
o pera4on.
2. Damaged
C ontrol
V alve.
3. Dust
o r
d ebris
b uild-‐up
i nside
o f
h eater.
CORRECTIVE
A CTION
1. No
c orrec4ve
a c4on
i s
n eeded.
1. No
c orrec4ve
a c4on
i s
n eeded.
1. Check
c urrent
t o
e lectric
o utlet.
I f
v oltage
i s
c orrect,
check
p ower
c ord
a nd
e xtension
c ord
f or
2. Be
s ure
t hat
h ousing
i s
n ot
d amaged.
M ake
s ure
there
a re
n o
o bstruc4ons
t o
t he
f an.
3. Straighten
b lade(s)
t o
m atch
o thers.
4. Replace
m otor.
1. Check
i gnitor
w ire.
R e-‐aQach
o r
4 ghten
i f
l oose.
Check
S park
m odule.
R eplace
i f
n ecessary.
2. Set
g ap
( See
s pecifica4ons
f or
g ap).
3. Replace
S park
E lectrode.
1. If
t he
h eaters
o utput
i s
r estricted,
i nternal
t emperature
becomes
t oo
h igh.
M ove
h eater
a way
f rom
any
o bstruc4ons.
2. Replace
C ontrol
V alve.
3. Clean
i nside
o f
h eater.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!