Hi-flying Elfin-EE1 Series Manuale operativo - Pagina 7
Sfoglia online o scarica il pdf Manuale operativo per Adattatore Hi-flying Elfin-EE1 Series. Hi-flying Elfin-EE1 Series 15. Rs232/rs485 to wi-fi
- 1. Table of Contents
- 1. 1 Elfin-Ee1X Evk
- 1. Elfin-EE10 8PIN Connector
- 1. Elfin-EE11 8PIN Connector
- 1. Elfin Rj45 Cable
- 2. 2 Serial Setting
- 2. Serial Tool Securecrt
- 2. Configure Serial Parameter
- 3. 3 Test Example
- 3. Ethernet Direct Connect Networking
- 3. Tcp Server Test in Auto Ip Mode
- 3. Router Networking
- 3. Tcp Server Test
- 4. Appendix A:references
- 4. A.1.Test Tools
- 4. A.2.More Application
Operation Guide
Elfin-EE1X
3. TEST EXAMPLE
Elfin-EE1X use TCP/IP protocol for communication. There is two main parameters one for IP address
and another for port number.
3.1. Ethernet Direct Connect Networking
Auto-IP is used for local area when there is no DHCP server exist, devices will use the Class B
169.254 for communication. Connect device Ethernet with PC, the device will use default auto IP(Elfin
series use 169.254.1.1, others use 169.254.173.207). The PC may use this IP to config the device or
transfer data. As the following example
Step 1:Open IOTService and find the device.
3.2. TCP Server Test in Auto IP Mode
Step 1:Open TCP&UDP test tool and generate TCP connection as following steps. Device has
already created a TCP Server (port 8899) for use. TCP&UDP test tool can be downloaded from our
website:
⚫
DestIP:IP address of device which can be found by IOTService.
⚫
Port:Port of TCP Server which can be found by IOTService or set by users own.
http://www.hi-flying.com/
- 7 -