Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Pompa dell'acqua Hi-Force AHP-BTU Series. Hi-Force AHP-BTU Series 19. Air driven hydraulic pumps

The system operating pressure MUST NOT exceed the pressure rating of the lowest-rated
component in the system.
Good Practice:
Use a pressure gauge to monitor the entire system.
Only use hydraulic tools / cylinders in a complete and tested, coupled system. NEVER attempt to
use a tool / cylinder that is not correctly coupled to its operational pump.
NEVER pressurise an unconnected male coupler/s.
NEVER attempt to disconnect a hose from a hydraulic system until the system's pressure has
been completely released. Doing so can result in that pressure becoming trapped within the
system and relieving trapped pressure can be dangerous.
NEVER try to relieve trapped hydraulic pressure in the system by loosening or attempting to
remove the coupler. Trapped hydraulic pressure can cause a loosened coupler to dislodge
unexpectedly with great force. This action could result in serious personal injury or death.
Loosening a coupler under pressure can result in the escape of hydraulic oil at high pressure,
which can penetrate the skin and cause significant injury or death.
NEVER use a hammer and punch to unseat a coupler check valve that is under pressure. Doing
so could result in the sudden, uncontrolled release of hydraulic oil at high pressure, which could
cause significant injury or death.
NEVER attempt to solve, or clean-up leaks in the system while the system is pressurised.
Immediately replace any worn or damaged parts using genuine Hi-Force parts only.
DO NOT use any hydraulic equipment if you are under the influence of alcohol, drugs or
medication. Lack of attention whilst operating high-pressure hydraulic tools can result in personal
injury or death.
NEVER lift, carry, or move any hydraulic components by the hose or hoses connected to them.
Avoid damaging hydraulic hoses. ALWAYS route hoses to ensure that they are free from sharp
bends and kinks. Using a sharply bent or kinked hose will result in severe back-pressure, which
can lead to hose failure.
NEVER use a coupler/s to lift, carry or position a tool.
Servicing of hydraulic equipment must only be undertaken by a qualified technician.
DO NOT let familiarity gained with any hydraulic tools allow you to become complacent.
Complacency with any tooling can result in a lack of discipline toward working guidelines and
safety principles.
Failure to observe and obey the following safety precautions could result
in property damage, equipment damage or minor / moderate personal
injury;
DO NOT
drop or place heavy objects on a hydraulic hose, as this may
cause internal damage, which could result in rupture of the pressurised
hose. A ruptured hose could cause significant damage to components and
possible severe injury to personal operating nearby.
Operating Instruction Manual:
OM-AHP-BTU-01
4
Serial Numbers:
FROM BQ 9522