Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Pompa dell'acqua Hi-Force HEP310144. Hi-Force HEP310144 20. Electric driven pumps, general duty, medium/high flow
Hi-Force HEP2 & HEP3 electric driven hydraulic pumps should be serviced and repaired only by
authorised Hi-Force repair centres. The following table gives possible causes and solutions for common
Problem
1. Pump will not start.
2. Motor stalls before full
operating pressure is
reached.
3. Pump runs but will not
build up to full operating
pressure.
4. Noisy Operation
5. Pump builds to full
pressure, but
cylinder/tool does not
advance/operate.
6. Pump running hot.
10.0 Troubleshooting
problems.
TROUBLESHOOTING GUIDE
Possible Cause
a. Power not connected.
b. Damaged power cord.
c. Circuit breaker tripped.
d. Damaged pendant.
e. Blown fuse.
f. Burnt out motor.
a. Low supply voltage.
a. Reservoir breather has not been
installed.
b. Low oil level.
c. Adjustable relief valve incorrectly
set.
d. External oil leak in system.
a. Air trapped in the system.
b. Low oil level
c. Reservoir breather has not been
installed.
a. Advance or return flow line to
cylinder/tool restricted or blocked.
a. Low oil level.
b. Advance or retract flow restricted.
c. High pressure leakage at pump.
Operating Instruction Manual:
OM-HEP2/3-01
Solution
Connect power.
Repair or replace power cord.
i. Reset Circuit breaker.
ii. Ensure breaker is adequately rated.
Contact your local Hi-Force office/distributor.
Replace blown fuse.
Contact your local Hi-Force office/distributor.
i. Use heavier gauge extension cord.
ii. Turn off excess electrical loads.
Remove transit plate and install reservoir
breather as per section 5.1
Add oil as per section 5.2.
Adjust relief valve pressure as per
section 5.1.
Contact your local Hi-Force office/distributor.
Bleed air from the system as per section 5.5
Add oil as per section 5.2
Remove transit plate and install reservoir
breather as per section 5.1
Check couplers (if fitted) for full engagement.
Add oil as per section 5.2.
Check couplers (if fitted) for full engagement.
Contact your local Hi-Force office/distributor.
17
From Serial Number:
BQ3323