Dynablast BEF series Manuale dell'operatore - Pagina 8

Sfoglia online o scarica il pdf Manuale dell'operatore per Idropulitrice Dynablast BEF series. Dynablast BEF series 19. Hot water

WINTERIZING YOUR PRESSURE WASHER

(This is also good practice if the cleaner is to remain unused for more than 3-4 weeks.)
WITH A FLOAT BOX
1.
Shut off the water supply, and disconnect hose.
2.
You need a short (2') length of hose with a male garden hose fitting on one end.
3.
Connect the short hose to the inlet of the machine.
4.
Put the other end of the water hose into a container of windshield washer or anti-freeze.
5.
Turn on the Cleaner and open gun until liquid comes out of the nozzle "foamy" or "soapy".
6.
Put gun in "OFF" position for 5 seconds to get antifreeze into bypass line. Shut off motor, unit
winterized.
CAUTION - If your hose is longer than 35 feet, the float box may empty before the liquid from the nozzle gets
foamy. If this happens, refill the float box with antifreeze and continue.
MAINTENANCE SCHEDULE
WEEKLY
Check the oil level of the high pressure pump. If the oil is milky or the oil level is below the minimum mark,
change or fill with SAE 20W or 30W oil.
MONTHLY
Clean the filter in the float valve. (An old toothbrush can be used to scrub while the filter is held under running
water).
ANNUALLY
Clean the heating coil, descale the heating coil, clean the filter ahead of and in the oil pump, and check & reset
the combustion efficiency of the burner.

SERVICE AND MAINTENANCE

6
BEF
SERIES