Hi-Force HPF207412 Manuale di istruzioni per l'uso - Pagina 15

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Pompa dell'acqua Hi-Force HPF207412. Hi-Force HPF207412 16. Electric driven, general duty, medium flow

5. Pump builds to full
pressure, but cylinder
does not operate.
6. Pump running hot.
7. Cylinder not
functioning correctly.
8. Cylinder will not
retract.
9. Gauge displays no
capacity reading.
a. Advance or return flow line to
cylinder restricted or blocked.
a. Low oil level.
b. Advance or retract flow restricted.
c. High pressure leakage at pump.
a. Cylinder incorrectly connected to
pump.
b. Pump solenoid faulty.
c. Cylinder fault.
d. Low oil level
e. Air trapped in the system
a. Valve malfunction.
b. Return flow line restricted or
blocked.
a. Faulty gauge.
b. Pump will not build pressure.
Operating Instruction Manual:
OM-HPF PUMP-01
Check couplers for full engagement.
Add oil as per section 5.2.
Check couplers for full engagement.
Contact your local Hi-Force office/distributor.
Check for correct system setup. Check
couplers for full engagement
Contact your local Hi-Force office/distributor.
See cylinder troubleshooting guide or contact
your local Hi-Force office/distributor.
Add oil as per section 5.2.
Bleed air from the system as per section 5.4
Contact your local Hi-Force office/distributor.
i. Check couplers for full engagement.
ii. Run motor while retracting cylinder.
Contact your local Hi-Force office/distributor
See problem 3 above.
15
From Serial Number:
BS8412