Aircommand IBIS Manuale di installazione e istruzioni per l'uso - Pagina 11
Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Condizionatore d'aria Aircommand IBIS. Aircommand IBIS 15.
9. ATTACH PLENUM COVER
- Secure the main plenum cover to the
duct assembly with the 4 screws
provided (Fig 16).
TIP: It is important that these screws
are not over tightened otherwise the
plenum may crack.
- Remove the filter elements by pulling
them out of the plenum, and use the six
self tapping counter sunk screws to
secure the covers edges to the caravan
ceiling (Fig 17). In some instances a very
Fig 15: Attaching the suspension cable will allow two hands free to plug in
small pilot hole may need to be drilled
the control cable
to guide the screws into place.
- Replace the filters by sliding them into
the plenum until they click into place
-Your installation is now complete.
Fig 16: Secure the main plenum cover to the duct assembly with the four
screws provided
Fig 17: Remove the plenum filters and use the six self tapping screws to
secure the plenum over to the ceiling of the caravan. Be sure not to over tighten.