5.3 Bleeding Trapped Air from the System
Cylinders and hoses are not always completely filled with oil when new. It is not usually necessary to bleed
air from single-acting cylinders. However, you MUST ensure that all hydraulic hoses are pre-filled with oil
before connection, to ensure no additional air is introduced into the system.
NEVER extend any HVL cylinder unless its base is fully supported and an external load
is present.
The bleeding of trapped air from a hydraulic system must only be performed by
qualified personnel who have been trained and are competent to do so.