Gaggenau VG 264 220 CA Manuale di istruzioni per l'installazione - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Piano di cottura Gaggenau VG 264 220 CA. Gaggenau VG 264 220 CA 15.
Anche per Gaggenau VG 264 220 CA: Manuale d'uso e manutenzione (20 pagine)

Gaggenau VG 264 220 CA Manuale di istruzioni per l'installazione
9 IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS

Electric Safety

9
WARNING
Before you plug in an electrical cord
or turn on power supply, make sure
all controls are in the OFF position.
For appliances equipped with a cord and
plug, do not cut or remove the ground
prong. It must be plugged into a matching
grounding type receptacle to avoid
electrical shock. If there is any doubt as
to whether the wall receptacle is properly
grounded, the customer should have it
checked by a qualified electrician.
Do not use an extension cord.
Do not use an adapter.
If required by the National Electrical
Code (or Canadian Electrical Code), this
appliance must be installed on a separate
branch circuit.
The circuit breaker should have a contact
separation of at least 3 mm on all poles.
Be sure your appliance is properly
installed and grounded by a qualified
technician. Installation, electrical
connections and grounding must comply
with all applicable codes.
Before installing, turn power OFF at the
service panel. Lock service panel to
prevent power from being turned ON
accidentally.
Installer – show the owner the location of
the circuit breaker or fuse. Mark it for
easy reference.

Gas Safety

Install a gas shutoff valve near the
appliance. It must be easily accessible in
an emergency.
Leak testing must be conducted by the
installer according to the instructions in
this manual.
The appliance and its individual shutoff
valve must be disconnected from the gas
supply piping system during any pressure
testing at pressures in excess of ½ psi
(3.5 kPa).
The appliance must be isolated from the
gas supply piping system by closing its
individual manual shutoff valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less
than ½ psi (3.5 kPa).
The minimum supply pressure must be 1"
water column above the manifold
pressure printed on the rating label.
The maximum supply pressure must not
exceed 14.0 inches water column
(34.9 Millibars).
IMPORTANT SAFETY NOTICE: Burning
gas cooking fuel generates some by-
products which are on the list of
substances which are known by the State
of California to cause cancer or
reproductive harm. To minimize exposure
to these substances, always operate this
unit according to the instructions
contained in this booklet and provide
good ventilation.
5