Hi-Link HLK-RM08K Manuale d'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale d'uso per Unità di controllo Hi-Link HLK-RM08K. Hi-Link HLK-RM08K 13. Uart to ethernet application
Anche per Hi-Link HLK-RM08K: Manuale d'uso (7 pagine), Manuale d'uso (9 pagine)

Hi-Link HLK-RM08K Manuale d'uso
www.hlktech.net Email :[email protected] skype:hlktech
Parameter storage :
RCFG:The parameters in the memory.
SCFG:General parameters.
CCFG:Save To C Instructions to save parameters.
FCFG:Factory factory Settings. Users can't modify.
1. Power on,module read SCFG to RCFG from flash.
2. Save instructions RCFG to SCFG.
3. Restore settings,copy CCFG to SCFG.
4. Save To C Save instructions RCFG to CCFG.
5. Factory resetting,copy FCFG to CCFG.

2.3 TYPICAL REFERENCE DESIGN

2.3.1 UART TO ETHERNET
6