Gaggenau AF210192 Manuale d'uso e istruzioni di montaggio - Pagina 11

Sfoglia online o scarica il pdf Manuale d'uso e istruzioni di montaggio per Cappa di ventilazione Gaggenau AF210192. Gaggenau AF210192 16.
Anche per Gaggenau AF210192: Manuale d'uso e istruzioni per l'installazione (16 pagine)

Gaggenau AF210192 Manuale d'uso e istruzioni di montaggio
Depending on the appliance specifications
12.2 Safety clearances
Comply with the safety clearances for the appliance.
 12.3 Secure installation
Follow these safety instructions when in-
stalling the appliance.
WARNING ‒ Risk of poisoning!
Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the flue or the extraction
shaft are sucked back into the living space.
▶ Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room air-dependent heat-producing appli-
ance is being operated.
▶ It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
drop more than 4 Pa (0.04 mbar) below at-
mospheric pressure. This can be achieved
whenever the air needed for combustion is
able to enter through openings that cannot
be sealed, for example in doors, windows,
in conjunction with incoming/exhaust air
wall boxes or by other technical means. An
incoming/exhaust air wall box alone does
not ensure compliance with the limit.
▶ In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.
▶ Unrestricted operation is possible if the ap-
pliance is operated exclusively in air recir-
culation mode.
WARNING ‒ Risk of suffocation!
Children may put packaging material over
their heads or wrap themselves up in it and
suffocate.
▶ Keep packaging material away from chil-
dren.
▶ Do not let children play with packaging ma-
terial.
WARNING ‒ Risk of fire!
Grease deposits in the grease filter may catch
fire.
▶ The specified safety clearances must be
complied with in order to prevent a build-up
of heat.
▶ Observe the specifications for your cooking
appliance. If gas and electric hobs are be-
ing operated together, the largest specified
clearance applies.
▶ The appliance must be installed with no
more than one side directly next to a high-
sided unit or a wall. The distance between
the appliance and wall or high-sided unit
must be at least 50 mm.
Grease deposits in the grease filter may catch
fire.
▶ Never work with naked flames close to the
appliance (e.g. flambéing).
▶ Do not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-remov-
able cover is available. There must be no
flying sparks.
WARNING ‒ Risk of injury!
Components inside the appliance may have
sharp edges.
Installation instructions en
11