Gaggenau CG261210AU Istruzioni per l'utente - Pagina 9
Sfoglia online o scarica il pdf Istruzioni per l'utente per Piano cottura Gaggenau CG261210AU. Gaggenau CG261210AU 20.
Gas connection
During the planning stage, consider the position of
supply connections.
The cooktop must be connected to the gas supply with
upstream connection of an isolation valve in accordance
with the respectively valid regulations. We recommend
that the isolation valve be fitted prior to the cooktop to
enable isolation of cooktop from gas supply. The valve
must be easily accessible at all times.
To find out the factory set gas type, see bottom of
cooktop next to gas connection.
Remove plastic cap from gas supply line prior to
installation.
Fit regulator (N.G.) or a test point (Universal LPG)
directly to the R 1/2'' connection.
Direction of gas flow is indicated on the rear of the
regulator.
Position of the inlet connection:
Use pipe compound or thread sealant, properly
threaded pipes and careful assembly procedure so that
there is no cross threading, etc., which might cause
damage or leakage.
Make sure that all connections performed are free of
leakage. The manufacturer does not accept any liability
for leakage on connections performed by the installer or
if the L-tube is moved or twisted.
There are two ways to carry out the connection to the
main gas line:
▯
The hotplate can be connected with rigid pipe as
specified in AS/NZS 5601.1
▯
Flexible Hose: If installing with a hose assembly, it
must comply with AS/NZS 1869, 10 mm ID, class B
or D, no more than 1.2 m long and installed in
accordance with AS/NZS 5601.1.
Installation and connection
Ensure that the hose does not contact the hot
surfaces of the hotplate, oven, dishwasher or any
other appliance that may be installed underneath or
next to the hotplate. The hose should not be
subjected to abrasion, kinking or permanent
deformation and should be able to be inspected
along its entire length with the cooktop in the
installed position. Unions compatible with the hose
fittings must be used and all connections tested for
gas leaks.
The supply connection point shall be accessible with
the appliance installed.
WARNING: Ensure that the hose assembly is restrained
from accidental contact with the flue outlet of an
underbench oven.
Before Leaving
Check all connections for gas leaks with soap and
water. DO NOT use a naked flame for detecting leaks.
Ignite all burners both individually and concurrently to
ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and observe
stability of the flame for each burner individually and all
together. Adhere the duplicate data plate to an
accessible location near the hotplate. When satisfied
with the hotplate, please instruct the user on the correct
method of operation. In case the appliance fails to
operate correctly after all checks have been carried out,
refer to the authorised service provider in your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When
being repaired, the appliance must always be
disconnected from the mains supply; if required, notify
our customer service.
Converting the cooktop from Nat. Gas
to Universal LPG
All work involved in installation, setting and adaptation
to a different gas type must be carried out by a licensed
gas fitter and must comply with current regulations and
the conditions laid down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important: After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
en
9