Ambient temperature and ventilation

Ambient temperature
The climate class can be found on the rating plate.
The climate class indicates within which ambient
temperatures the appliance can be operated.
Climate
Permitted ambient
class
temperature
SN
+10 °C to 32 °C
N
+16 °C to 32 °C
ST
+16 °C to 38 °C
T
+16 °C to 43 °C
Note
The appliance is fully functional within the room
temperature limits of the indicated climatic class. If
an appliance of climatic class SN is operated
at colder room temperatures, the appliance will not
be damaged up to a temperature of +5 °C.
Ventilation
Conduction of the heated air must not be obstructed.
Otherwise, the refrigeration unit must work harder.
This increases power consumption. Therefore: Never
cover or block the ventilation opening!

Connecting the appliance

Have a technician install and connect the appliance
according to the enclosed installation instructions.
Do not remove the transportation protection devices
from the shelves and storage compartments until
the appliance has been installed.
In addition to the statutory national regulations,
observe the connection conditions of the local power
supply companies.
After installing the appliance, wait at least 1 hour until
the appliance starts up. During transportation the oil
in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
"Cleaning the appliance").
6
Electrical connection
The socket must be near the appliance and also freely
accessible following installation of the appliance.
m
Warning
Risk of electric shock!
If the length of the mains cable is inadequate, never
use multiple sockets or extension leads. Instead,
please contact Customer Service for alternatives.
The appliance complies with protection class I.
Connect the appliance to 220–240 V/50 Hz
alternating current via a correctly installed socket with
protective conductor. The socket must be protected by
a (10–16 A) fuse.
For appliances operated in non-European countries,
check whether the indicated voltage and current type
match the values of your electricity supply. This
information can be found on the rating plate (see
chapter entitled Customer Service).
m
Warning
Never connect the appliance to electronic energy
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters
are used for photovoltaic systems which
are connected directly to the national grid. Sine-
controlled inverters must be used for isolated
applications (e.g. on ships or in mountain lodges)
which are not connected directly to the national grid.