Maintenance, care and servicing/ repair

8.2 Maintenance

DANGER!
All work on electrical and pneumatic systems may
only be carried out by qualified personnel who have
been trained to do so and are familiar with the risks
involved.
NOTE!
Observe the check intervals for pressure vessels
(see chapter "Checking operational safety").
DANGER!
Electric shock is life-threatening!
There is a danger of life in case of contact with cur-
rent running through components.
- Always disconnect the mains plug before you start
cleaning and maintenance works.
- Connections and repairs of the electrical equip-
ment may only be carried out by specialized elec-
trical staff.
ATTENTION!
Before starting any maintenance work, switch off the
compressor and allow it to cool completely.
Completely drain the compressed air. The container
and the lines must not be under pressure.
ATTENTION!
After maintenance, repair and cleaning works,
check if all covers and protective equipment are
properly reassembled to the compressor and that
there are no more tools inside or in the working area
of the compressor.
Inform the dealer or the customer service in case of
damaged protection devices.
Use protective gloves!
Use safety shoes!
Wear protective clothes!
12
Step 1: Before performing any maintenance, turn off
the compressor, disconnect the power plug,
and drain all air from the reservoir.
Daily:
Step 2:
Before starting work, check the compressed
air lines for damage and replace them if
necessary.
Use safety gloves!
Step 3:
Drain the condensed water by opening the
valve below the tank. Close the valve again as
soon as only air flows out without condensed
water. Protective gloves must be worn for this.
A flat container is recommended to catch the
condensed water.
Every 6 months:
Step 2:
Open the safety valve (Fig. 6) by pulling the
ring outwards (the pressure tank must be un-
der pressure) until the compressed air audibly
blows off. Then release the ring.
1
Fig. 6:
Safety valve
ATTENTION!
The safety valve is set to the maximum pressure of
the pressure vessel. Es ist nicht zulässig, das
Sicherheitsventil zu verstellen oder dessen Plombe
zu entfernen.
Step 3:
Thoroughly clean all components that have
ribs or fins.
AIRBOY | Version 1.07