ADEMCO Ademco VISTA-20P Manuale di programmazione - Pagina 6

Sfoglia online o scarica il pdf Manuale di programmazione per Sistema di sicurezza ADEMCO Ademco VISTA-20P. ADEMCO Ademco VISTA-20P 17. Programming auto arming and disarming schedules
Anche per ADEMCO Ademco VISTA-20P: Manuale di installazione rapida (2 pagine), Manuale d'uso (20 pagine), Manuale di programmazione (17 pagine), Manuale di avvio rapido (6 pagine), Manuale di installazione rapida (2 pagine), Manuale di installazione rapida (2 pagine), Manuale di programmazione (2 pagine), Manuale rapido (2 pagine)

ADEMCO Ademco VISTA-20P Manuale di programmazione
MISCELLANEOUS SYSTEM FIELDS (*174-*181)
∗ ∗ ∗ ∗ 174
Clean Me Reporting Options
(for ESL smoke detectors)
0 = disable; 1 = Clean Me signal reports;
NOTE: If Clean Me is enabled, you must enter "3" in field ✱56
programming for zone 1 response time.
∗ ∗ ∗ ∗ 177
Device Duration 1, 2
(used in *80 Menu mode-Device Actions 5/6)
0 = 15 seconds
6 = 2-1/2 min
1 = 30 seconds
7 = 3 min
2 = 45 seconds
8 = 4 min
3 = 60 seconds
9 = 5 min
4 = 90 seconds
#+10 = 6 min
5 = 2 minutes
∗ ∗ ∗ ∗ 181
50/60 Hertz AC Operation
0 = 60 Hz; 1 = 50 Hz
CONFIGURABLE ZONE TYPE OPTIONS (*182-*185)
(see Configurable Zone Type Worksheet on page 7)
∗ ∗ ∗ ∗ 182
Configurable Zone Type 90
1
2
3
4
5
Enter the appropriate value for each entry, 1-10, based on the charts
provided on the next page. Each entry is the sum of the values of its
selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
∗ ∗ ∗ ∗ 183
Zone Type 90 Report Codes
IMPORTANT: Use existing Contact ID® codes, if appropriate, or
define unique codes in CID code range 750-789. See important note
in installation instructions.
90 ALARM ID: XXX
TROUBLE ID: XXX
Enter the desired 3-digit Contact ID® report codes for alarms and
troubles occurring on zones assigned to this zone type. Enter the
codes sequentially (all 6 digits). When entering digits, [#] moves
cursor back, [∗] moves forward. Press [∗] when done to continue.
∗ ∗ ∗ ∗ 184
Configurable Zone Type 91
1
2
3
4
5
Enter the appropriate value for each entry, 1-10, based on the charts
provided on the next page. Each entry is the sum of the values of its
selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
∗ ∗ ∗ ∗ 185
Zone Type 91 Report Codes
IMPORTANT: Use existing Contact ID® codes, if appropriate, or
define unique codes in CID code range 750-789. See important note
in installation instructions.
91 ALARM ID: XXX
TROUBLE ID: XXX
Enter the desired 3-digit Contact ID® report codes for alarms and
troubles occurring on zones assigned to this zone type. Enter the
codes sequentially (all 6 digits). When entering digits, [#] moves
cursor back, [∗] moves forward. Press [∗] when done to continue.
∗ ∗ ∗ ∗ 189
AUI Device 1 and 2 Enable
(for Touch Screen Style Keypads)
System supports up to two touch screen style keypads (e.g., Symphony
Advanced User Interface, and 6270 Touch Screen Keypad).
AUI Compatibility Note: To ensure proper AUI device operation,
connect only to controls having microprocessor version 3.0 or higher,
and use AUI devices with the following rev levels: 6270 series use
version 1.0.9 or higher; 8132/8142 (Symphony) series use version
1.1.175 or higher.
Touch Screen (AUI) device 1: Must set AUI device address to 1
Touch Screen (AUI) device 2: Must set AUI device address to 2
VISTA-20P: Enter each touch screen keypad's home partition
0 = disable; 1 = partition 1; 2 = partition 2; 3 = partition 3 (common)
VISTA-15P: 0 = disable; 1 = enable
NOTE: Use of touch screen style keypads does not affect the number
of standard keypads supported.
[0]
[0] [0]
1
2
#+11 = 7 min
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min
[0]
6
7
8
9
10
6
7
8
9
10
[1] [1]
AUI 1
AUI 2
– 6 –
KEYPAD OPTIONS *190-*196
NOTES: 1. Options for keypad address 16 are set by the factory and cannot
be changed.)
2. Each keypad must be assigned a unique address. Keypads
programmed with the same address will give unpredictable results.
∗ ∗ ∗ ∗ 190
Keypad 2 Device Address 17
†Partition/Enable:
VISTA-20P: Enter partition where:
0 = keypad disabled; 1-3 = part. no. (3 = com)
VISTA-15P: 1 = enable; 0 = disable
Sound:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime beeps
∗ ∗ ∗ ∗ 191
Keypad 3 Device Address 18
See field ∗190 for entries.
∗ ∗ ∗ ∗ 192
Keypad 4 Device Address 19
See field ∗190 for entries.
∗ ∗ ∗ ∗ 193
Keypad 5 Device Address 20
See field ∗190 for entries.
∗ ∗ ∗ ∗ 194
Keypad 6 Device Address 21
See field ∗190 for entries.
∗ ∗ ∗ ∗ 195
Keypad 7 Device Address 22
See field ∗190 for entries.
∗ ∗ ∗ ∗ 196
Keypad 8 Device Address 23
See field ∗190 for entries.
∗ ∗ ∗ ∗ 197
Exit Time Display Interval
0 = no display; 1-5 = seconds between display refresh
NOTE: If enabled and using only 2-digit fixed-word keypads (e.g.,
6150RF), do not set exit delay time greater than 96 seconds. See Inst.
Instr. for explanation.
∗ ∗ ∗ ∗ 198
Display Partition Number
(VISTA-20P; for Alpha Display Keypads)
0 = no; 1 = yes (partition no. appears on Alpha Display)
∗ ∗ ∗ ∗ 199
ECP Fail Display
0 = 3-digit display ("1" + device address)
1 = 2-digit fixed-display as "91"
[0] [0]
Part./ Sound
Enable
[0] [0]
Partition/
Sound
Enable
[0] [0]
Partition/
Sound
Enable
[0] [0]
Partition/
Sound
Enable
[0] [0]
Partition/
Sound
Enable
[0] [0]
Partition/
Sound
Enable
[0] [0]
Partition/
Sound
Enable
[0]
[0]
[0]