DYNACO Stereo 70 Manuale di restauro - Pagina 19

Sfoglia online o scarica il pdf Manuale di restauro per Amplificatore DYNACO Stereo 70. DYNACO Stereo 70 20. Series ii tube amplifier
Anche per DYNACO Stereo 70: Manuale di restauro (5 pagine), Manuale d'uso (12 pagine), Istruzioni per il montaggio (16 pagine)

DYNACO Stereo 70 Manuale di restauro
Dynaco Stereo 70 Power Amplifier
Restoration Manual
Detailed Procedure & Guide
Page 19
R0 4-03
Addendum 2 Dynaco Stereo-70 Post Storage Startup Procedure
Dynaco vacuum tube amplifiers incorporate components that may undergo
electrochemical changes if left in a de-energized state over a long period (approximately
6 months). To preserve the operation of the components and operator safety is it
generally recommended that the reapplication of power be conducted in a controlled
manner. It is the purpose of this document to describe a suitable procedure for the typical
owner without access to laboratory test equipment.
The following components and test equipment will be required:
1. Digital DVM (inexpensive model from Radio Shack or equivalent)
2. 100K ohm / 3 to 5 Watt Resistor
3. 3" length of 1/8" heat shrink tubing
Procedure:
1. You will first remove the top and bottom covers by removing the 4 (6 on some units)
located on the right and left sides of the amplifier. Both covers should be free to be
released.
2. Remove the rectifier tube (GZ-34).
3. Connect the amplifier to 120VAC mains.
4. Switch on the amplifier (for approximately 1 minute). Examine the four output tubes
and two small driver tubes to confirm the illumination of the filaments.
5. Locate the 7 pin terminal strip on the underside of the amplifier to the left of the power
transformer. Using your digital voltmeter (set to DC volts) Measure the DC voltage on
lug # 4 (counting from the left edge of the amplifier) and confirm a reading of
approximately negative 65 VDC (+/- 10%) relative to the chassis. Failure to achieve this
voltage suggests a defective selenium rectifier or other bias supply problems.
6. Switch off the amplifier and disconnect from the AC mains.
7. Remove the remainder of the tubes (4X output, 2X 7199 driver) and label to identify
for re-positioning later. Install the Rectifier tube (GZ-34).
8. De-solder the red wire connected to lug 2 (See figure 1) of the Dynaco Quad
electrolytic capacitor (the other end is connected to V1/pin8).
9. Slide the 3" length of the 1/8" heat shrink tubing down the free length of the red wire
removed during the previous step. Tack solder one end of the 100K ohm / 3Watt resistor
to the free end of the red wire removed in the previous step. Slide the heat shrink tubing
upwards to completely cover the exposed any wire including the resistor lead. Connect
the remaining free end of the 100K / 3Watt resistor to lug #2 of the Dynaco quad
electrolytic capacitor.
10. Set your voltmeter to DC volts and set the range of your voltmeter to be capable of
reading 500VDC. Securely connect the Black Test lead of your voltmeter to V1/pin8.
Securely connect the remaining Red Test lead to Lug # 2 of the Dynaco Quad electrolytic
capacitor. During the tests that follow it is important to remember that your DVM will be
19