ADEMCO LYNX Manuale d'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale d'uso per Sistema di sicurezza ADEMCO LYNX. ADEMCO LYNX 17.
Anche per ADEMCO LYNX: Manuale di avvio rapido (8 pagine), Manuale del sistema (14 pagine)
VOICE DESCRIPTOR
0 = Skip to next zone (A)
1 = Enter descriptor mode (existing zone descriptor will be announced, then descriptor 1 will be repeated)
DESCRIPTOR 1
d
vv
Enter [#] + 2-digit vocabulary index † number ( vv ) of first descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 2 (descriptor 2 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
DESCRIPTOR 2
vv
Enter [#] + 2-digit vocabulary index † number ( vv ) of second descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 = accept word and advance to descriptor 3 (descriptor 3 will be announced)
8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
DESCRIPTOR 3
vv
Enter [#] + 2-digit vocabulary index † number ( vv ) of third descriptor word for this zone.
To change the entered index number, press [#] + desired index number.
6 or 8 = accept word and advance to next zone (prompt A) – zone descriptor will be announced
Press any other key to repeat the selected word
† See *84 ASSIGN ZONE VOICE DESCRIPTORS section for Vocabulary Index.
*80 POWERLINE CARRIER DEVICE PROGRAMMING
Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. Press *80 while in
programming mode. NOTE: Entry of a number other than one specified will give unpredictable results.
Powerline Carrier Device Programming
0 = Exit mode, upon which this prompt blinks. Press [*] + any field number to go to that field.
1 = Enter mode
DEVICE NUMBER
Enter the 2-digit device number (01-08) to be programmed
[*] = Continue
00 = Exit Device Programming mode (
DEVICE ACTION
b
aa
Enter the 1-digit action, 0-3, for the device being programmed (current action is displayed).
0 = No response
1 = Close for 2 seconds
2 = Close and stay closed
START EVENT TYPE (if applicable)
et
Enter the 1-digit start event type, 0-3, for the device being programmed.
0 = Not used
1 = Alarm
2 = Fault
START ZONE LIST (if applicable)
d
zl
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[*] = Continue
[#] = Return to previous prompt
START ZONE TYPE (if applicable)
zt
Enter the 2-digit start zone type for the device being programmed ( see Powerline Carrier Device
Worksheet for zone type/system operation codes later in this manual).
[*] = Continue
[#] = Return to previous prompt
STOP ZONE LIST (if applicable)
zl
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[*] = Continue
[#] = Return to previous prompt
STOP ZONE TYPE (if applicable)
zt
Enter the 2-digit stop zone type for the device being programmed ( see Powerline Carrier Device
Worksheet for zone type/system operation codes later in this manual).
[*] = Return to Device Number prompt (A)
[#] = Return to previous prompt
displays blinking 80; enter
3 = Pulse on and off
[*] = Continue
[#] = Return to previous prompt
3 = Trouble
[*] = Continue
[#] = Return to previous prompt
9 –
–
*
+ desired data field or menu mode number)