Local programming requires the use of a 2-line alpha keypad (e.g., 6139) connected to the keypad terminals on the control.
Field Function
[
] = Default Value
20 INSTALLER CODE
Enter 4 digits, 0–9
21 QUICK ARM ENABLE
1 = enable: 0 = disable
22 RF SYSTEM TYPE
0 = none; 2 = 5800 (5881/5882)
4 = 5800 w/ RF Jam Detection
23 FORCED BYPASS FUNCTION
0 = none; 1 = bypass faulted zones
24 RF HOUSE ID CODE
00 = disable all wireless keypad usage;
01–31 = when using 5827 and 5827BD keypad
28 SINGLE ALARM SOUNDING/ZONE
0 = no limit; 1 = once per arming period
UL Installations: Must be 0.
29 FIRE SOUNDER TIMEOUT
0 = fire sounder timeout; 1 = no fire sounder timeout.
30 ALARM BELL TIMEOUT
0 = none; 1 = 4 min; 2 = 8 min;
3 = 12 min; 4 = 16 min
UL Installations: Must be set to 1 (minimum).
In fields 40, 41, and 42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; # +11 for ;
# +12 for #; # +13 for a pause.
40 PABX ACCESS CODE
Enter up to 4 digits if PABX code is needed to access an
outside line. If fewer than 4 digits are entered, do not fill
unused spaces.
Exit by pressing
(and press 41, if entering next field). To
clear entries from this field, press 40 .
41 PRIMARY PHONE NO.
|
|
Enter up to 12 digits; do not fill unused spaces. If fewer than
12 digits entered, exit by pressing
entering next field). To clear entries from this field, press
41 .
42 SECONDARY PHONE NO.
|
|
Enter up to 12 digits; do not fill unused spaces. If fewer than
12 digits entered, exit by pressing
entering next field). To clear entries from this field, press
42 .
† Entry of a number other than one specified will give unpredictable results.
Programming Form
To set all program fields to ADEMCO default values: Press 97.
Programmed Values
SYSTEM SETUP ( 20 – 30)
|
|
[4 1 1 1]
[0]
[0]
[0]
[00]
ZONE SOUNDS AND TIMING ( 28 – 39)
[0]
[0]
[1]
DIALER PROGRAMMING ( 40 – 50)
|
|
|
|
|
|
|
|
|
|
(and press 42, if
|
|
|
|
|
|
|
|
(and press 43, if
Field Function
|
25 OUTPUT RELAY MODULE
0 = none; 3 = 4204
26 VOICE MODULE ACCESS CODE
1st digit: Enter 1-9;
2nd digit: Enter only # + 11 for , # + 12 for #.
0 in either position = disables phone module
27 OUTPUT TO LONG RANGE RADIO
0 = no; 1 = yes. If yes selected, dialer reports to Primary
No. (field 47) will also be sent via LRR. All dialer and LRR
reports will be in Contact ID ® format (overriding field 46)
|
UL Installations: Must be set to 0.
38 ENTRY DELAY
0 = 0 sec; 1 = 20 sec; 2 = 30 sec; 3 = 45 sec;
4 = 60 sec; 5 = 90 sec
UL Installations: 45 seconds (maximum).
EXIT Delay = ENTRY Delay + 15 sec.
39 AUDIBLE EXIT WARNING
0 = no; 1 = yes
|
43 SUBSCRIBER ACCOUNT NUMBER
Enter 0–9; # +11 for B; # +12 for C; # +13 for D;
# +14 for E; # +15 for F. Enter
reporting is to be used. Enter 0 as the first digit of a 4-digit
account number for Nos. 0000-0999.
Exit by pressing
To clear entries from this field, press 43 .
|
Examples:
For Acct. No. 1234, enter:
For Acct. No. B234, enter:
For Acct. No. 123, enter:
|
45 PHONE SYSTEM SELECT
If Cent. Sta. is NOT on a WATS line:
If Cent. Sta. IS on a WATS line:
– 5 –
[
] = Default Value
Programmed Values
as 4th digit if 3+1 dialer
(and press next field).
0 = Pulse Dial; 1 = Tone Dial;
2 = Pulse Dial; 3 = Tone Dial
[0]
|
[0]
[0]
[2]
[1]
| | |
1 | 2 | 3 | 4
#+11| 2 | 3 | 4
1 | 2 | 3 |
[1]