Quick start guide
 1
Connect wiring to EMC-ALRM
PLM IN to PLM on EMCS for high-rise or on
EMC-60 phone for low-rise (additional phones
in same group connected in series)
12-24VDC Power (Note polarity)
PLM LED (Note polarity)
KEY SWITCH (Normally Open, momentary
close spring return)
 2
With power applied, the green 'NORMAL' LED
should be on.
For Low-Rise test:
Select PLM test on the EMC-60 elevator phone.
WAKE PROG 2 4 ENTER
Touch
test time in seconds and touch
For High-Rise test:
Disconnect phone line to the CAB at the EMCS. Try
calling the cab for quick test to verify alarm.
Reconnect to reset then repeat but wait for alarm.
 3
The EMC-ALRM red 'ALARM' LED on the PCB will
illuminate, the buzzer will "beep" once every 30
seconds and the PLM LED flash.
 4
Silence the buzzer with the key switch. The EMC-
ALRM orange 'SILENCE' LED will illuminate and the
PLM LED continue flashing.
 5
For Low-Rise test:
After the PLM Test time expires on the EMC-60
phone the EMC-ALRM green 'NORMAL' LED will
illuminate and the PLM LED stop flashing.
For High-Rise test:
Reconnect the phone line to reset.
Customer Care: Call 1-844-EMERCOM (1-844-363-7266) for assistance.
EMC-ALRM User Guide
, select the
ENTER
.
- 2 -