HiB iCLASS SE R90 Manuale di installazione - Pagina 3

Sfoglia online o scarica il pdf Manuale di installazione per Punto di accesso wireless HiB iCLASS SE R90. HiB iCLASS SE R90 7.

PLT-01051, A.3

Specifications

PRODUCT
BASE PART NUMBER
R90
940N
NSC = Normal Standby Condition
1
Communications protocols other than Wiegand or Clock
& Data require an additional hardware module which
increases current by 30 mA."
1
Mounting
CAUTION: RFID readers can be influenced by conditions in the installation environment. The R90 reader is designed to be
mounted on a metal gooseneck pedestal as shown in this guide. However, in the event the reader must be mounted onto a large
metal surface, it may be necessary to mount the reader off of the metal surface using a NEMA style electrical box. In the USA,
an example of such a box used at HID facilities is P/N PCH196 from The Housing Company.
8.00
5.30
INPUT VOLTAGE (VDC)
Standby
AVG
12 VDC
110 mA
24 VDC
70 mA
2
Standby AVG - RMS current draw without a card in
the RF field.
3
Maximum AVG - RMS current draw during
continuous card reads. Not evaluated by UL.
Peak - highest instantaneous current draw during
RF communication.
US JBOX
EU JBOX
2.36
3 25
7.00
5 00
US JBOX
CURRENT
1
OPERATING TEMPERATURE
Max
PEAK
4
2
AVG
3
130 mA 300 mA
-30 - 150 F
(-35 - 65 C)
80mA
150 mA
11.00
9 00
Gasket intended to cover drilled holes.
Cut gasket as needed.
iCLASS SE
R90
CABLE LENGTH
UL REF NUMBER
Power Supply Lines
300 ft (91 m)
- 22 AWG
780 ft (237 m)
- 18 AWG
Communication Lines
R90Ex
x
x
Wiegand / Clock-and-Data
1
2
500 ft (152 m)
- 22 AWG
300 ft (91 m)
- 24 AWG
RS485
4,000 ft (1,219 m) - 24 AWG
UL Reference Number Deciphering
x
Reader Colors:
K = Black, G = Gray
1
x
Wiring:
T = Terminal
2
x
Communications: N = No Module
3
R = RS485 (OSDP)
3