Celect SAS908XWHB-7-DF1 Manuale - Pagina 4

Sfoglia online o scarica il pdf Manuale per Controllore Celect SAS908XWHB-7-DF1. Celect SAS908XWHB-7-DF1 10. Waterline master control controller

Celect SAS908XWHB-7-DF1 Manuale
2. Setting Temp – Room Temp ≥1℃, heating output on (Fast heating or slow heating, see configuration
menu 6 items)
3. Room Temp – Setting Temp ≥1℃, heating output off,
In standby mode press ③ button under the above three seconds, Through the
adjustment according to the ④ buttons preservation.
Step
Press buttons
(factory default)
1
Press P Button
2
Press P Button
3
Press P Button
4
Press P Button
5
Press P Button
6
Press P Button
7
Press P Button
8
Press P Button
9
Press P Button
10
Press P Button
11
Press P Button
2.display for implied parameters:
In standby mode, shortly press button
more than 3seconds, enter implied parameters setting; the first item, setting the temperature coefficient: Press
change set temperature, short press button
when long press button
Configuration setting
Displayed
Press▲、▼to select
( )
-
℃(
℃(
℉)—
( )
(
)
( )
( )
(
)
(
)
(
)
to start; Shortly hold
more than 3 seconds, show that DEF flash 3 times, all parameters setting return to
Select temperature display adjustment higher or
--- +
lower
Select maximum room temperature limitation
℉)—
℃(
℉)
℉) Select minimum room temperature limitation
℃(
Changes the display readout to Centigrade or
/
Fahrenheit as required
Backlight mode
:no backlight
/
/
:backlight maintain 5 sec
:backlight maintain 15 sec
Start heating conditions: when setting temperature
< room temperature from the heat, when setting
~
temperature ≥ room temperature reduction db
parameters start heating
Program option
: 7 days separately (Refer table 1 and table
2) ;
/ / /
: 5+1+1(Refer to table 3 and table 4)
: 5+2(Refer to table 5 and table 6)
: Non programmable
Programming period in one day option
/
6-6 time zones;4-4 time zones;
Time scale
/
: 24hour system;
Intelligent Recovery Option
:Without intelligent function
/
:Active intelligent function
Language
/
Chinese/English.Factory default: English.
enter modify the time;Long press
enter implied parameters, setting other parameters,
4
After
button adjustment,
Descriptions
: 12hour system