Initial filling

The lubricant reservoir must be depressurized before filling the lubricant.
For the first use of the system, it is recommended to fill the lubricant reservoir before
connecting it to the compressed air supply.
If the system is already connected to the compressed air supply, it must be ensured that the
lubricant supply tank has been depressurized before filling.
To make the lubricant reservoir unpressurised, first disconnect the system from the
compressed air supply by disconnecting the system from the air line or closing the main valve
(8 Figure 2).
When the main valve is closed, the tank pressure is relieved via this valve.
Check that the pressure has been completely removed. The manometer must show the value
'zero'.
If you are sure that the pressure has been completely relieved, you can now open the filling
plug (12 Fig. 2) and fill the lubricant.
Attention:
Only suitable minimum quantity lubricants may be used as lubricants.
Please note that we cannot assume liability for damage caused by the use of
unsuitable lubricants.
Be sure to close the filler plug after filling.