Dayva HS041-2 Manuale di istruzioni - Pagina 5
Sfoglia online o scarica il pdf Manuale di istruzioni per Riscaldatore Dayva HS041-2. Dayva HS041-2 19. Premier outdoor heater
FOR YOUR SAFETY
READ BEFORE OPERATING
If you do not follow these instructions exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
A. This appliance operates with a Safety Pilot System. It is important that the pilot lights before the burner
can light.
B. BEFORE OPERATING, smell all around the appliance area for gas. Be sure to smell next to the floor
because some gas is heavier (PROPANE) than air and will settle on the floor. (NATURAL GAS WILL
RISE)
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electric switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in
or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas control
which has been under water.
E. Quick disconnects are not recommend because of possible gas leaking from connections.
CHOOSING A LOCATION
The heater may be installed on a combustible
floor surface. If the heater is installed near a
combustible wall or ceiling surface, the following
minimum clearances must be maintained:
18 in. from any ceiling surface, and 24 in. from
any wall on all sides.
This appliance is CSA Certified for outdoor installation
only in a well ventilated space. The installation of this
appliance must conform with local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1-Latest Edition. It must not be used
in a building, garage, or any enclosed area or structure.
The ground surface used for installation must be firm
and level, and allow adequate ventilation around the
unit (a minimum of 24 in. clear per side). At no time
should any part of the L.P. cylinder enclosure be
blocked off.
WARNING:
5
18" FROM ANY
CEILING SURFACE
24" FROM
ANY WALL
ON ALL SIDES