HID MaxiProx DFM Reader - 5375 Manuale di installazione - Pagina 16

Sfoglia online o scarica il pdf Manuale di installazione per Lettore di schede HID MaxiProx DFM Reader - 5375. HID MaxiProx DFM Reader - 5375 19.

HID MaxiProx DFM Reader - 5375 Manuale di installazione
Part No. 5375-901, Rev E.1
4.1.5 Example Output
The following is an example of an ID card with the number of "
MaxiProx reader, the number "
Note: The customer code is never transmitted or displayed.
customer code 10 zeros
[0 0 0 0 0 0 1] [0 0 0 0 0 0 0 0 0 0] [1] [0] [0 1 1 0 0 1 0 1] [0 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0] [1]
|
0
Wiegand Output
Hex code numbers
Decimal conversion
4.2

Clock-and-Data Interface

The following sections outline the MaxiProx Clock-and-Data Interface.
4.2.1 Message Format
The Clock-and-Data interface consists of three signals, Card Present, Data and Strobe/Clock. The
interface is a serial data stream, which is controlled with a clock/strobe that indicates when data is
valid. All signals are quiescent high. Card Present goes low when data is about to be sent and
remains low until the whole data stream is completed. Data is the signal that determines the "ones"
and "zeros". Strobe/Clock is the signal that indicates when data is valid for each cycle.
The Track 2 message format is a stream of binary bits that are grouped into HEX characters. The
message starts with leading zeros, followed by a start sentinel, data, end sentinel, LRC and trailing
zeros. Each HEX character has error correction in the form of a parity bit. Each character consists of
five bits. The maximum number of characters for a magnetic strip card encoded on Track 2 are 40, this
product will output less than 40 characters. The data consists only of
A
F
digits,
to
, are used for the start and end sentinel, data separators and control. Only hex
A, C D
used,
and
The bits of a character are in the order
Xoring of the message, starting with the start sentinel and ending with the end sentinel. The LRC does
not include the parity bits of the characters in the Xoring. LRC does include its own odd parity bit that
covers the four bits that are the result of the Xoring.
Customer code
format. The data on these cards will be packed into the Track 2 format in segments of three bits, so
the character does not exceed a
Page 16 of 19
02004CA0661
sentinel parity
bit even facility code
|
2
|
0 |
0 |
E
are not used. The message will consist of a minimum of 210 bits.
1248P
<leading zeros><Start Sentinel><data><data>........<data><End sentinel><LRC><trailing zero>
0,1, 63, 72
73
and
(existing customer codes) cards will be read and output in the Track 2
BCD
seven.
© 2008 - 2012 HID Global Corporation. All rights reserved.
816
" decimal, which will be output by the
" hex.
card number
4
|
C |
A
|
0 |
| 0 |
C |
A
|
0 |
[
6
| 5
][ 0
|
[
101
][
, where parity is odd over the four bits. The LRC is the
®
MaxiProx
Installation Guide
parity
odd
6
|
6
|
1
6
|
6
|
1
3 |
3 |
0 ]
0816
]
BCD
digits, the remaining HEX
March 2012
B
F
and
are