HID pivCLASS RK40-H Manuale di installazione - Pagina 3
Sfoglia online o scarica il pdf Manuale di installazione per Lettore di schede HID pivCLASS RK40-H. HID pivCLASS RK40-H 8.
I N STALLATI ON GUI DE
2
Wiring
BEEP (YEL)
GRN LED (ORN)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED LED (BRN)
HOLD (BLU)
GPIO1(RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1 (WHT)
DATA2 (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
Pigtail Reader
(Module position varies)
Pigtail
Terminal
Yellow
P1-1
Orange
P1-2
Black
P1-3
Red
P1-4
Drain
P1-5
Brown
P1-6
Blue
P1-7
*RS-485 applicable for pivCLASS readers.
**Tamper Output - When activated, output synchronizes to ground (default).
***Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
h id g l o b a l.co m
Beeper
GPIO1
GRN LED
GP102
GND
OC/TMPR
+VDC
DATA1/CLK
DRAIN
DATA2/DATA
RED
GPIO3
HOLD
GPIO4
18 in
(0.46 m)
(Terminal block and module
Description
Beeper Input
LED Input (GRN)
Ground (RTN)
+VDC
Unused
LED Input (RED)
Hold Input
An ASSA ABLOY Group brand
pivCLASS
R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
P1
Notes:
P2
Terminal Reader
position varies)
Pigtail
Terminal
Red / Green
P2-7
Tan
P2-6
Violet
P2-5
White
P2-4
Green
P2-3
Pink
P2-2
Gray
P2-1
RPKCL40-P, RKCLB40-P
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
1. Previous iCLASS readers had reversed RS-485 wiring
(P2-7 & P2-6 - A & B). When upgrading to a pivCLASS
reader, ensure proper connections as defined below.
2. Wiring the reader incorrectly may permanently damage
the reader.
3. For cable lengths greater than 200 ft. (61 m) or EMF
interference, install 120Ω +/- 2Ω resistor across
RS-485 termination ends.
4. It is possible to reuse existing Wiegand wiring for
OSDP, however, using simple stranded cable (typical of
Wiegand access control readers) usually does not meet
RS-485 twisted pair recommendations.
Description
*GPIO1/OSDP (RS485-FDX/HDX-A)
*GPIO2/OSDP (RS485-FDX/HDX-B)
**Open Collector Output / Tamper
***Wiegand Data 1 / Clock
***Wiegand Data 0 / Data
*GPIO3 (RS485-FDX-Z)
*GPIO4 (RS485-FDX-Y)