HID EDGE EVO EH400-K Manuale di installazione - Pagina 11

Sfoglia online o scarica il pdf Manuale di installazione per Controllore HID EDGE EVO EH400-K. HID EDGE EVO EH400-K 13. Standard networked controller

HID EDGE EVO EH400-K Manuale di installazione
I N STALLATI ON GUI DE
B.2

Internal Optical Tamper

The Controller Optical Tamper can not be disabled. The Optical Tamper is suppressed by properly
installing the back plate which contains a post with white paint on it and securing it to the unit. To
disable the internal module optical tamper sensors:
• Right side of PCB (reader interface board): attach a jumper wire from P2 pin 10 to P2 pin 5.
• Left side PCB (door interface board): attach a jumper wire from P3 pin 1 to P3 pin 2.
CAUTION: The EH400-K ships from HID Global with these jumpers pre-installed on the connectors.
Removing these jumpers causes false tampers to trigger.
Note: If desiring an external tamper, wire an unsupervised Normally Closed contact, replacing one of
the pre-installed jumpers.
B.3

Relay Jumpers

AUX Wet
AUX Wet
CAN V+
+12VDC
3
1
3
JUMPER =
B.4

Tamper (Reader Interface Board)

The Reader Tamper + and - are implemented allowing a connection for an open collector external
tamper from a reader, such as iCLASS.
Note: Connect P2, Pin 2 (GND) from the Reader Interface Board to the same ground as the reader
power if the reader is not powered by the unit's 12 VDC output port.
B.5

Door Interface Board Groups 1 and 2

Following are the inputs for Group 1 and Group 2 configurations.
Input
AC -
AC +
BATT -
BATT +
REX -
REX +
Door Mon -
Door Mon +
DS Wet
AUX Dry
CAN V+
1
3
1
3
P9
P5
P8
Group 1
Port
Pin
P3
Pin3
P3
Pin 4
P3
Pin 5
P3
Pin 6
P3
Pin 7
P3
Pin 8
P3
Pin 9
P3
Pin 10
An ASSA ABLOY Group brand
EDGE EVO
DS Wet
DS Dry
+12VDC
1
3
1
3
Input
Input 4 -
Input 4 +
Input 3 -
Input 3 +
Input 2 -
Input 2 +
Input 1 -
Input 1 +
Page 11
82000-921, Rev. D.3
1
P6
P4
P7
Group 2
Port
P3
Pin3
P3
Pin 4
P3
Pin 5
P3
Pin 6
P3
Pin 7
P3
Pin 8
P3
Pin 9
P3
Pin 10
Pin