HID Aero X300 Manuale di installazione - Pagina 7

Sfoglia online o scarica il pdf Manuale di installazione per Unità di controllo HID Aero X300. HID Aero X300 7. Output control module

Specifications
HID AERO X300
Input Voltage
Maximum Input Current
IO Module
Inputs
Output Relays
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Humidity
MECHANICAL
Dimension
Weight
These specifications are subject to change without notice.
12 to 24 V DC ± 10%
500 mA
2-wire RS-485, 2,400 to 115,200 bps, asynchronous,
half-duplex, 1 start bit, 8 data bits, and 1 stop bit
Five unsupervised/supervised, standard EOL: 1k/1k, 1%, ¼ watt
(Includes TAMPER, AC FAIL, and BATT FAIL inputs)
UL evaluation for access control use only
Twelve Form-C relays. Contact rating: 2 A @ 30 V DC resistive
32 to 158°F (0 to +70°C)
-67 to 185°F (-55 to +85°C)
5 to 85% RHNC
6.46" × 5.51" × 1.02" (164 mm × 140 mm × 26 mm)
342 g
HID Aero™ X300 Installation Guide