HID Technology solutions 1101 Manuale d'uso - Pagina 13

Sfoglia online o scarica il pdf Manuale d'uso per Sistemi Rfid HID Technology solutions 1101. HID Technology solutions 1101 19. Uhf rfid reader for the motorola mc70/75/75a

HID Technology solutions 1101 Manuale d'uso

TROUBLESHOOTING AND MAINTENANCE

MAINTENANCE

For trouble-free service treat the 1101 UHF tt in the same way as you would the MC70/75 and observe the following
tips when using the 1101 UHF Reader:
Do not store or use the 1101 UHF Reader in any location that is dusty, damp, or wet.
Protect the 1101 UHF Reader from temperature extremes. Do not leave it on the dashboard of a car on a hot
day, and keep it away from heat sources.

TROUBLESHOOTING

Symptoms
The Application on the MC70/75
cannot communicate with the
1101 UHF Reader.
The 1101 UHF Reader does not
read a particular transponder
MC70/75 battery does not charge
ActiveSync cannot connect to the
MC70/75
Copyright © Technology Solutions (UK) Ltd 2021
Possible cause
The MC70/75 is not firmly seated
into the 1101 UHF Reader.
The port has not been opened.
The port is in use by another
application.
The 1101 UHF Reader has been
configured to exclude some
transponders based on a mask
value.
The transponder is out of range of
the 1101 UHF Reader.
The transponder has been
inventoried into a persistent
session.
The battery is faulty.
Ambient temperature is too warm. Move the unit to an area where the
The MC70/75 is not firmly seated
into the 1101 UHF Reader.
ActiveSync is not correctly
configured on the PC or the
MC70/75.
The MC70/75 is not firmly seated
into the 1101 UHF Reader.
13
Action
Remove and re-insert the MC70/75 from
the 1101 UHF Reader, ensuring it is
firmly seated.
Check that the Application has been
configured to use COM1.
Close the other application and try
again.
Correct the mask value.
Move the transponder closer to the
antenna.
Wait for the session persistence to
expire, use a different session or use a
different target flag.
Verify that other batteries charge
properly. If so, replace the faulty battery.
ambient temperature is between 0°C
and 35°C.
Remove and re-insert the MC70/75 from
the 1101 UHF Reader, ensuring it is
firmly seated.
Detach the 1101 UHF Reader from the
MC70/75 and try to ActiveSync directly
to the MC70/75. If this does not work
then consult the MC70/75 User Guide.
Remove and re-insert the MC70/75 from
the 1101 UHF Reader, ensuring it is
firmly seated.
1101 UHF Reader User Guide V1.51
www,tsl.com